0.75KW Frequency Converter 220V Single Phase/380V 3 Phase Input Variable Frequency Inverter

$153.37
  Availability: In Stock
  Shipping: Free Airmail 
  Estimated Delivery: 

+
  •   Shipping Methods

    Handling Time

    Before we can ship your order, we prepare your products, do strict quality-control tests and carefully package the items. The time it takes to prepare your items for shipping is separate from the delivery time. It usually takes 1-3 business days to ship out .

    Shipping Methods

    You can choose the preferred shipping method on the cart page during the checkout process. We offers 3 international shipping methods:

    1. Airmail – Free untracked economy shipping via national postal services (HK Post, Singapore Post, China Post, PostNL, Swiss Post, Sweden Post, USPS, Royal Mail e.t.c.)
    2. Airmail Registered – Tracked shipping via national postal services (HK Post, Singapore Post, China Post, PostNL, Swiss Post, Sweden Post, USPS, Royal Mail e.t.c.)
    3. Expedited Shipping – Express shipping with courier delivery (DHL, UPS, FedEx, TNT)

    Delivery Time

    Airmail and Airmail Registered Area Estimated Delivery Time
    United States, Canada 7-25 business days
    Australia, New Zealand, Singapore, United Arab Emirates 10-25 business days
    United Kingdom, France, Spain, Germany, Netherlands, Japan, Belgium, Denmark, Finland, Ireland, Norway, Portugal, Sweden, Switzerland 10-25 business days
    Italy, Brazil, Russia, South Africa 10-45 business days
    Other countries 10-35 business days
    Expedited Shipping 3-10 business days to Worldwide

    Note: If you choose an expedited shipping, please remember to leave a valid contact number, this is required for expedited shipping’s courier delivery.

  •  Returns & Refund

    Last updated October 05, 2022

    Returns

    If you are not completely satisfied with your purchase for any reason, you may return it to us for a full refund within 15 days from delivery date. All returned items must be in new and unused condition, with all original tags and labels attached.

    Return Process

    To return an item, please email our customer service at sales@alexnld.com to obtain a Return Merchandise Authorization (RMA) number. After receiving a RMA number, place the item securely in its original packaging, and mail your return to the following address:

    Alex NLD
    Attn: Returns
    RMA #
    HaGiborim St 8
    Tiberias, 14388
    Israel

    Please note, you will be responsible for the return shipping charges. We strongly recommend that you use a trackable method to mail your return.

    All customers should contact us and obtain Return Merchandise Authorization (RMA) number before sending anything to us. We will not be responsible for returned item(s) without notifying us in advance.

    Refunds

    After receiving your return and inspecting the condition of your item, we will process your refund to the credit / debit card or PayPal account which was used to place the original order.

    Please allow at least seven (7) days from the receipt of your item to process your refund. Refunds may take 1-2 billing cycles to appear on your credit card statement, depending on your credit card company. We will notify you by email when your refund has been processed.

    Exceptions

    If an item is found damaged or defective on receipt, we kindly ask you to contact us within 15 days from the delivery date to arrange a refund or exchange without physical return of the item.

    Please provide us with following:

    1. Photos of the front and back sides of the packaging box;
    2. A photo, video or screenshot of the defective item or the defective part of the parcel.

    Our customer service team will communicate with you to arrange a refund or reshipment without physical return of the item.

    Warranty & Repair service

    If any of the items you have purchased from us is found defective within 1 year from receipt, you are entitled to a repair under warranty. Please kindly provide us with evidence photos or videos of the defective item. After providing such information to our Customer Service team  and the problem is acknowledged, you can send the items back to us for a repair.

    Note:  Please be aware, we do not cover the cost of the returns fees in  warranty & repair service.

    Order Cancellation

    If you want to cancel an order within 24 hours from confirmation of the payment, you will be entitled to a full refund. It is still possible to cancel an order after 24 hours, provided that it has not yet been shipped. If an order has been shipped, it’s impossible for us to cancel or modify it anymore. If you still want a refund, you required to return the item on it’s arrival.

    Questions

    If you have any questions concerning our return policy, please contact us at:

    +972 054-536-2888
    sales@alexnld.com

     


  Share
Specification:

Power 0.75KW
Output 220V or 380V
Output frequency range 0.01-400Hz The maximum frequency can be set arbitrarily between 25.00-400.0Hz
Voltage single phase: 220V ± 15%; three phase: 380V ± 15%
Frequency 50-60Hz ± 5%
Control mode full digital space voltage vector SVPWM algorithm; carrier frequency 1-12 KHz continuously adjustable.
Starting frequency 0.00- 25.00Hz can be set arbitrarily
Output frequency resolution 0.01Hz
Frequency setting 0.01Hz:
Resolution Analog input (external terminal) setting: 1% of the highest frequency
V/F characteristics linear VF; base frequency can be set freely between 25.00 and 400.0 Hz
Torque compensation linear torque compensation mode, compensation voltage range: 0-30%
Overload capability 150% rated current 1 minute; 180%, rated current 2 seconds.
Stop mode deceleration stop / free stop
Acceleration and deceleration time 0.1-6000 seconds (acceleration, deceleration can be set separately)
 

Features:
— This product is a high performance frequency converter, the power is 1.5KW, the input is three-phase 380V/50HZ, the output is three-phase 380V/ 0-400HZ.

 
— Input end is connected to R S T, output end is connected to U V W motor.
 
— Widely used in: pump control flow, constant pressure water supply, engraving machine, printing machinery, packaging equipment, fan speed and other industries.
 
— Widely used in power electronics and transmission industry at home and abroad, energy saving transformation, used in power, textile and chemical fiber, building materials, petroleum, chemical, metallurgy, municipal, paper, food and beverage, to-bacco and other industries and public works (central air conditioning, water supply, water treatment, elevators, etc.).

Wiring Instructions, Danger Tips:
1. Before wiring, please confirm that the input power has been cut off.
There is a risk of electric shock and fire.
 
2. Wiring work must be performed by an electrical engineering professional.
There is a risk of electric shock and fire.
 
3. The grounding terminal must be reliably grounded.
There is a risk of electric shock and fire.
 
4. After the emergency stop terminal is connected, be sure to check if its action is valid.
There is a danger of injury. (The wiring responsibility is borne by the user)
 
5. Do not touch the output terminal directly. Do not connect the output terminals of the inverter to the housing, and do not short-circuit the output terminals.
 There is a risk of electric shock and short circuit.
 
Note: 
1. Please confirm whether the AC main circuit power supply and the rated voltage of the inverter are consistent. There is a risk of injury and fire.
2. Do not perform voltage withstand test on the inverter. Can cause damage to semiconductor components, etc.
3. Connect the brake resistor or brake unit according to the wiring diagram. There is a danger of fire.
4. Tighten the terminal with a screwdriver of the specified torque. There is a danger of fire.
5. Do not connect the input power cable to the output U.V.W terminal. The voltage is applied to the output terminals, which can cause internal damage to the inverter.
6. Do not connect the phase shift capacitor to the output loop. This can cause internal damage to the inverter.
7. Do not connect the electromagnetic switch or electromagnetic contactor to the output circuit. When the inverter is running with load, the inrush current generated by the action of the electromagnetic switch and the electromagnetic contactor will cause the overcurrent protection circuit of the inverter to operate.
 
Product protection features:
— After the inverter has abnormal conditions, the protection circuit and the fault output relay are activated, and the fault is displayed and stopped. Please find the cause of the fault and the corresponding countermeasures, and then solve the fault and then run. The inverter has over current. Intelligent power module protection, under voltage protection, over voltage protection, over temperature protection, overload protection. (Please refer to the manual for details on the product usage and parameter introduction)


Package Included:
1 x Inverter
 

Reviews

There are no reviews yet.


Be the first to review “0.75KW Frequency Converter 220V Single Phase/380V 3 Phase Input Variable Frequency Inverter”

Your email address will not be published. Required fields are marked *


Q & A

There are no questions yet

Ask a question

Your question will be answered by a store representative or other customers.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Thank you for the question!

Your question has been received and will be answered soon. Please do not submit the same question again.

Error

Warning

An error occurred when saving your question. Please report it to the website administrator. Additional information:

Add an answer

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Thank you for the answer!

Your answer has been received and will be published soon. Please do not submit the same answer again.

Error

Warning

An error occurred when saving your answer. Please report it to the website administrator. Additional information:

Product ID: 7501142 Category: Voltage: 220V (+1 more)
Close My Cart
Close Wishlist
Close

Close
Navigation
Categories