3Pcs J03 LED Digital Time Delay Relay DC 6-30V On Off Trigger Delay Timming Timer Switch Micro USB Power Supply 5V 12V

$29.79
  Availability: In Stock
  Shipping: Free Airmail 
  Estimated Delivery: 
   Bulk Savings (Buy more save more)
+
  •   Shipping Methods

    Handling Time

    Before we can ship your order, we prepare your products, do strict quality-control tests and carefully package the items. The time it takes to prepare your items for shipping is separate from the delivery time. It usually takes 1-3 business days to ship out .

    Shipping Methods

    You can choose the preferred shipping method on the cart page during the checkout process. We offers 3 international shipping methods:

    1. Airmail – Free untracked economy shipping via national postal services (HK Post, Singapore Post, China Post, PostNL, Swiss Post, Sweden Post, USPS, Royal Mail e.t.c.)
    2. Airmail Registered – Tracked shipping via national postal services (HK Post, Singapore Post, China Post, PostNL, Swiss Post, Sweden Post, USPS, Royal Mail e.t.c.)
    3. Expedited Shipping – Express shipping with courier delivery (DHL, UPS, FedEx, TNT)

    Delivery Time

    Airmail and Airmail Registered Area Estimated Delivery Time
    United States, Canada 7-25 business days
    Australia, New Zealand, Singapore, United Arab Emirates 10-25 business days
    United Kingdom, France, Spain, Germany, Netherlands, Japan, Belgium, Denmark, Finland, Ireland, Norway, Portugal, Sweden, Switzerland 10-25 business days
    Italy, Brazil, Russia, South Africa 10-45 business days
    Other countries 10-35 business days
    Expedited Shipping 3-10 business days to Worldwide

    Note: If you choose an expedited shipping, please remember to leave a valid contact number, this is required for expedited shipping’s courier delivery.

  •  Returns & Refund

    Last updated October 05, 2022

    Returns

    If you are not completely satisfied with your purchase for any reason, you may return it to us for a full refund within 15 days from delivery date. All returned items must be in new and unused condition, with all original tags and labels attached.

    Return Process

    To return an item, please email our customer service at sales@alexnld.com to obtain a Return Merchandise Authorization (RMA) number. After receiving a RMA number, place the item securely in its original packaging, and mail your return to the following address:

    Alex NLD
    Attn: Returns
    RMA #
    HaGiborim St 8
    Tiberias, 14388
    Israel

    Please note, you will be responsible for the return shipping charges. We strongly recommend that you use a trackable method to mail your return.

    All customers should contact us and obtain Return Merchandise Authorization (RMA) number before sending anything to us. We will not be responsible for returned item(s) without notifying us in advance.

    Refunds

    After receiving your return and inspecting the condition of your item, we will process your refund to the credit / debit card or PayPal account which was used to place the original order.

    Please allow at least seven (7) days from the receipt of your item to process your refund. Refunds may take 1-2 billing cycles to appear on your credit card statement, depending on your credit card company. We will notify you by email when your refund has been processed.

    Exceptions

    If an item is found damaged or defective on receipt, we kindly ask you to contact us within 15 days from the delivery date to arrange a refund or exchange without physical return of the item.

    Please provide us with following:

    1. Photos of the front and back sides of the packaging box;
    2. A photo, video or screenshot of the defective item or the defective part of the parcel.

    Our customer service team will communicate with you to arrange a refund or reshipment without physical return of the item.

    Warranty & Repair service

    If any of the items you have purchased from us is found defective within 1 year from receipt, you are entitled to a repair under warranty. Please kindly provide us with evidence photos or videos of the defective item. After providing such information to our Customer Service team  and the problem is acknowledged, you can send the items back to us for a repair.

    Note:  Please be aware, we do not cover the cost of the returns fees in  warranty & repair service.

    Order Cancellation

    If you want to cancel an order within 24 hours from confirmation of the payment, you will be entitled to a full refund. It is still possible to cancel an order after 24 hours, provided that it has not yet been shipped. If an order has been shipped, it’s impossible for us to cancel or modify it anymore. If you still want a refund, you required to return the item on it’s arrival.

    Questions

    If you have any questions concerning our return policy, please contact us at:

    +972 054-536-2888
    sales@alexnld.com

     


  Share

Features:

1. Wide voltage power supply (6 ~ 30V), supports microUSB 5.0V power supply, easy to use;
2. The interface is clear and simple, powerful, easy to understand, meet almost all your needs;
3. The emergency stop function (“STOP’key);With reverse polarity protection, reverse polarity will not burn the product.
4. Increase the sleep mode, if this mode is enabled, without any operation within 5 minutes, then automatically turn off the monitor, any key wake-up;
5. You can set a different OP, CL, LOP parameters, which are independent of each other, and are automatically saved;
6. After the module is powered down, all parameter settings are not lost.


Product parameters:


1: Operating voltage: 6–30V, support microUSB 5.0V power supply
2: Trigger Source: Active-high (3.0V-24V), have optocoupler isolation, can improve the system’s anti-jamming capability (customers can also shorting common ground).
3: Output capability: You can control the DC 30VDC 5A or 220VAC 5A device.
4: Quiescent Current: 20mA; Operating Current: 50mA
5: Life: more than 10 million times; Working temperature: -40
-85 ℃; Size: 6.2*3.8*1.7cm.

6: With optocoupler isolation, enhanced anti-jamming capability, industrial grade board.
Special Note: The relay outputs are passive contact, just a switch.

Operating mode:

P1: trigger signal, the relay is on ‘OP’ time, and then disconnect; in the ‘OP’ time, as follows:
P1.1: signal is triggered again, invalid
P1.2: signal is triggered again, the clock is reset
P1.3: Signal trigger again, relay off, stop the clock;
P-2: trigger signal, the relay off ‘CL’ of time, the relay on ‘OP’ time, and then disconnect relay;
P3.1: trigger signal, the relay is turned on after the ‘OP’ time, the relay off ‘CL’ time, then the operation cycle, if the trigger signal period, the relay off, stop the clock; the number of cycles ( ‘LOP ‘) can be set.
P3.2: without triggering signal, the relay is on ‘OP’ time, the relay off ‘CL’ time, and has been cycling; frequency ( ‘LOP’) cycle can be set;
P-4: signal holding function. If there is a trigger signal timing is cleared, the relay remains on; when the signal disappears, after the timing ‘OP’ time, the relay is; if another signal during timing, timing is cleared.

Timing range

0.1 seconds (min) to 999 minutes (max) continuously adjustable
How to choose the time range?
After setting the mode selection screen parameter value by a short press ‘STOP’ button to select the time range;
XXX. decimal point in the unit place, time range: 1 second to 999 seconds.
XX. X decimal point in decade place, Timing range: 0.1 seconds to 99.9 seconds
X. X. X. decimal full brightness, Timing range: 1 minute to 999 minutes.
For example, you want to set ‘OP’ is 3.2 seconds, then move the decimal point to decade place, the digital display 03.2
Parameter description: ‘OP’ – conduction time, ‘CL’ – off time, ‘LOP’ – the number of cycles (1-999 times, ‘—‘ represents infinite loop).
These parameters are independent of each other, but is shared by each mode. For example, in P1.1 mode, set the on-time ‘OP’ is 5 seconds, if you switch to P1.2 mode, it’s ‘OP’ will be 5 seconds too.
In the main interface (display 000), short press ‘SET’ button will display ‘OP’ ( ‘CL’, ‘LOP’) and the corresponding time XXX;
Some parameters only mode ‘OP’ (such as the mode P1.1, P1.2, P1.3), short press the ‘SET’ key to display only the “OP” and the corresponding time;
Some models have parameters ‘OP’,’CL’, ‘LOP’ (such as the mode P3.1, P3.2), short press ‘SET’ button will display ‘OP’ and the corresponding time, “CL” and the corresponding time, “LOP” and the corresponding number of times;
In the main interface by short press ‘SET’ key to see information about the parameters of the current mode, very convenient!

How to set parameters:

1. First, read the instructions to determine the required operating mode.
2. The module is powered up, the display at the current work mode (P1.1 default mode), then enter the main interface; press ‘SET’ button for 2 seconds after release to enter mode selection interface; a short time by pressing ‘UP’, ‘DOWN’ key to select the mode (P1.1 ~ P-4).
3. Select the mode (such as P3.2), short press the ‘SET’ button, then the parameter to be set flashes ( ‘OP’on-time, ‘CL’ off time, ‘LOP’ cycles ( ‘—‘ represents infinite loop)), by ‘UP’, ‘DOWN’ keys to adjust the  parameter value, support long press (rapid increase or decrease) and short press (increase or decrease one unit); then short press the ‘STOP’ key to select the decimal point position, select the time range (0.1            seconds to 999 minutes); short press the ‘SET’ button to set the next parameters of the current mode of  procedure is as above.
4. After the parameters are set, long press ‘SET’ button for 2 seconds then release, the name of the current mode will flash once, and then return to the main screen, set the parameters of success!
The main interface: In the relay does not work status display ‘000’ (no decimal point), with a decimal point under relay state.
Mode selection screen: Long press the ‘SET’ key to enter, after setting is completed, long press the ‘SET’ key to exit back to the main screen.
‘STOP’ button extensions:

Relays enable mode:

1. ON: Relay allows conduction in the ‘OP’ on-time;
2. OFF: relay prohibit conduction is always closed;
In the main interface, short press the ‘STOP’ button to switch between ON and OFF, the current in which the state will flash, and then return to the main screen. (This feature is an emergency stop function, click off the relay)
Sleep mode:
1. ‘C-P’ Sleep mode: five minutes without any operation, the digital display automatically turns off, the program running as usual;
2. ‘O-d’ normal mode: digital display always open;
Press the ‘STOP’ button for two seconds and then release to switch ‘C-P’ and ‘O-d’ state, in which the current state of flashes and then return to the main screen.

Package Included:

3 x DC 1 Channel Time Delay Relay Module

3 x Shell Case

Reviews

There are no reviews yet.


Be the first to review “3Pcs J03 LED Digital Time Delay Relay DC 6-30V On Off Trigger Delay Timming Timer Switch Micro USB Power Supply 5V 12V”

Your email address will not be published. Required fields are marked *


Q & A

There are no questions yet

Ask a question

Your question will be answered by a store representative or other customers.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Thank you for the question!

Your question has been received and will be answered soon. Please do not submit the same question again.

Error

Warning

An error occurred when saving your question. Please report it to the website administrator. Additional information:

Add an answer

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Thank you for the answer!

Your answer has been received and will be published soon. Please do not submit the same answer again.

Error

Warning

An error occurred when saving your answer. Please report it to the website administrator. Additional information:

Product ID: 11489141 Category:
Close My Cart
Close Wishlist
Close

Close
Navigation