5M/10M DF96D Auto Water Level Controller AC220V 5A Din Rail Mount Float Switch With 3 Probes Pump

$29.99
  Availability: In Stock
  Shipping: Free Airmail 
  Estimated Delivery: 

+
  •   Shipping Methods

    Handling Time

    Before we can ship your order, we prepare your products, do strict quality-control tests and carefully package the items. The time it takes to prepare your items for shipping is separate from the delivery time. It usually takes 1-3 business days to ship out .

    Shipping Methods

    You can choose the preferred shipping method on the cart page during the checkout process. We offers 3 international shipping methods:

    1. Airmail – Free untracked economy shipping via national postal services (HK Post, Singapore Post, China Post, PostNL, Swiss Post, Sweden Post, USPS, Royal Mail e.t.c.)
    2. Airmail Registered – Tracked shipping via national postal services (HK Post, Singapore Post, China Post, PostNL, Swiss Post, Sweden Post, USPS, Royal Mail e.t.c.)
    3. Expedited Shipping – Express shipping with courier delivery (DHL, UPS, FedEx, TNT)

    Delivery Time

    Airmail and Airmail Registered Area Estimated Delivery Time
    United States, Canada 7-25 business days
    Australia, New Zealand, Singapore, United Arab Emirates 10-25 business days
    United Kingdom, France, Spain, Germany, Netherlands, Japan, Belgium, Denmark, Finland, Ireland, Norway, Portugal, Sweden, Switzerland 10-25 business days
    Italy, Brazil, Russia, South Africa 10-45 business days
    Other countries 10-35 business days
    Expedited Shipping 3-10 business days to Worldwide

    Note: If you choose an expedited shipping, please remember to leave a valid contact number, this is required for expedited shipping’s courier delivery.

  •  Returns & Refund

    Last updated October 05, 2022

    Returns

    If you are not completely satisfied with your purchase for any reason, you may return it to us for a full refund within 15 days from delivery date. All returned items must be in new and unused condition, with all original tags and labels attached.

    Return Process

    To return an item, please email our customer service at sales@alexnld.com to obtain a Return Merchandise Authorization (RMA) number. After receiving a RMA number, place the item securely in its original packaging, and mail your return to the following address:

    Alex NLD
    Attn: Returns
    RMA #
    HaGiborim St 8
    Tiberias, 14388
    Israel

    Please note, you will be responsible for the return shipping charges. We strongly recommend that you use a trackable method to mail your return.

    All customers should contact us and obtain Return Merchandise Authorization (RMA) number before sending anything to us. We will not be responsible for returned item(s) without notifying us in advance.

    Refunds

    After receiving your return and inspecting the condition of your item, we will process your refund to the credit / debit card or PayPal account which was used to place the original order.

    Please allow at least seven (7) days from the receipt of your item to process your refund. Refunds may take 1-2 billing cycles to appear on your credit card statement, depending on your credit card company. We will notify you by email when your refund has been processed.

    Exceptions

    If an item is found damaged or defective on receipt, we kindly ask you to contact us within 15 days from the delivery date to arrange a refund or exchange without physical return of the item.

    Please provide us with following:

    1. Photos of the front and back sides of the packaging box;
    2. A photo, video or screenshot of the defective item or the defective part of the parcel.

    Our customer service team will communicate with you to arrange a refund or reshipment without physical return of the item.

    Warranty & Repair service

    If any of the items you have purchased from us is found defective within 1 year from receipt, you are entitled to a repair under warranty. Please kindly provide us with evidence photos or videos of the defective item. After providing such information to our Customer Service team  and the problem is acknowledged, you can send the items back to us for a repair.

    Note:  Please be aware, we do not cover the cost of the returns fees in  warranty & repair service.

    Order Cancellation

    If you want to cancel an order within 24 hours from confirmation of the payment, you will be entitled to a full refund. It is still possible to cancel an order after 24 hours, provided that it has not yet been shipped. If an order has been shipped, it’s impossible for us to cancel or modify it anymore. If you still want a refund, you required to return the item on it’s arrival.

    Questions

    If you have any questions concerning our return policy, please contact us at:

    +972 054-536-2888
    sales@alexnld.com

     


  Share
Features:
 
This product uses the integrated circuit, combined with the high-rise buildings, the sink (water tower) is designed to enhance the level classification has joint control under the sink, sink drainage and water protection and other functions, can automatically tank water, drainage, and effective pool water level to prevent water overflow or pump idling high damage, is an industrial, household products are applicable very suitable for urban, rural, school, where mining enterprises and domestic water wells.
Well Water Project, is widely used in printing and dyeing, chemical, food, beverage, wine, sugar and other industries.

Specification:
 
Model: DF96D
Voltage Range: AC220V
Max Current: 5A
Max Pump: 550w
Dimension: 88mm*50mm*67mm
Installation: Din Rail Mount
Operation:

(A) single control head on the sink installation instructions to install the control diagram shown in Figure 
 
A (warp) – is the tank (water tower) upper level control point, the water level rises to reach point A water level, water in contact with the probe, the controller automatically shuts the water they pump;
B (blue line) – the upper pool (water tower) the lower level control point, the water level drops below the water table to point B, the probe out of contact with water, the water level controller automatically open the pump, pool filled with water;
C (black line) – for the pool (water tower) ground, the lowest point on the tank in contact with the bottom of the pool;
D (green line), E (yellow line) points and received C
 
(B) under the control of a single pool (ie drainage pond) probe installation instructions to install the two shown in Figure:
 
E-limit pond level control for the next point, the water reached the point E are rising water level, water in contact with the probe, the water level controller automatically open the pump, pond drainage; Without drainage, the E point is not connected ;
 
D-limit for the next pond level control point, the water level dropped to D level, water control head disengagement, water level controller automatically shuts the pump to stop the drainage basin;
C-ground pool is the lowest point to put in contact with the bottom of the water tank;
A, B point is not connected.
 
(C) water protection probe installation instructions to install the diagram shown in Figure 3:
 
C, D point to the lower pool level control point, the water level down to the lower level, C, D probe and the surface of the disengagement, water level controller relay immediate action, cut output, the pump stopped working;
Point C and point E shorted;
A, B point is not connected.
 
(D) joint control up and down the pool installation instructions to install the probe is shown in Figure III:
A-is the pool (water tower) ceiling level control point, the water level rises to reach point A water level, water control head contact, the controller automatically shuts the water they pump;
 
B-is the pool (water tower) limit their fluid control point, the water level drops below the water table to point B, water and probe disengagement, automatic level control pump, pool filled with water;
C-upper, without the pool (water tower) public online, on the lowest point of contact with the bottom of the sink basin;
D-limit for the next pond level control point, the water level dropped to D level, water and probe disengagement, water level controller automatically shuts the pump to stop the drainage basin;
E-limit pond level control for the next point, the water level rises to the point E water level, water in contact with the probe, the water level controller automatically open the pump, pond discharge head; Without drainage, the E point is not connected.

Other installation instructions
1. In order to ensure the normal work of the liquid level controller, please check again after installed input and output of the wiring, probe connections are reliable contact. It can move up, down probe, make its contact, from the surface of the water, the simulated test of water controller is installed correctly and can according to your needs to work properly.
2. Proposed to each point probe fixed on the inner wall of the pool, in order to avoid the probe location deviation cause water level controller misoperation, (if the tank wall is a metal, in addition to the C point ground wire should not be in the wall, in order to avoid short-circuit, lead to water level controller does not work).
3. According to the above wiring method, check the products on the right side of the "manual/automatic switch (DF – 96 – d), whether it can according to user's need to manually open and close the water pump, after using the adjustment back to" automatic "position, water level controller.
4. Temporary need to open and close the water pump, please use the left side of the water level controller "manual/automatic switch control (DF – 96 – d) no manual switch.
5. To avoid misoperation, please do not install the product moisture, corrosion and high metal content gas environment.
6. It is recommended that you company produces the water level control use special probe. 
 
Troubleshooting
1. Connect the power does not work:
A. Look for light red power indicator light, if not, check whether the input and output terminals are good contact;
B. Check product on the left side of the "manual/automatic switch", whether in the "off" the adjustment will be back to "automatic" position, water level controller.
2. Over or below the water line probe control point, the pump not automatically closed or open, please press the "auto/manual switch control pump manually. And check:
A. Probe whether the deviation in situ, the position is too high (low), cause the water level can't contact (out);
B. Upper and lower water level, ground probe whether connection with other lines, whether there is wrong or short circuit;
C. Probe rustily and falls off phenomenon, probe line with the product, the probe line contact with the probe whether the connection between the good;
D. C ground wire are placed on the pool bottom. 
 
Package Included:

1 x 
DF96D AC220V 5A Din Rail Mount Float Switch 
3 x 5M/10m Probes

Detail Pictures:
 













Reviews

There are no reviews yet.


Be the first to review “5M/10M DF96D Auto Water Level Controller AC220V 5A Din Rail Mount Float Switch With 3 Probes Pump”

Your email address will not be published. Required fields are marked *


Q & A

There are no questions yet

Ask a question

Your question will be answered by a store representative or other customers.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Thank you for the question!

Your question has been received and will be answered soon. Please do not submit the same question again.

Error

Warning

An error occurred when saving your question. Please report it to the website administrator. Additional information:

Add an answer

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Thank you for the answer!

Your answer has been received and will be published soon. Please do not submit the same answer again.

Error

Warning

An error occurred when saving your answer. Please report it to the website administrator. Additional information:

Product ID: 6506163 Category: Length: 10M (+1 more)
Close My Cart
Close Wishlist
Close

Close
Navigation
Categories