5Pcs ZK-TD4 DC 5V 12V 24V Trigger Cycle Timer Delay Controller Module 15A 400W MOS Control Switch 16-Work Mode

$31.19
  Availability: In Stock
  Shipping: Free Airmail 
  Estimated Delivery: 
   Bulk Savings (Buy more save more)
+
  •   Shipping Methods

    Handling Time

    Before we can ship your order, we prepare your products, do strict quality-control tests and carefully package the items. The time it takes to prepare your items for shipping is separate from the delivery time. It usually takes 1-3 business days to ship out .

    Shipping Methods

    You can choose the preferred shipping method on the cart page during the checkout process. We offers 3 international shipping methods:

    1. Airmail – Free untracked economy shipping via national postal services (HK Post, Singapore Post, China Post, PostNL, Swiss Post, Sweden Post, USPS, Royal Mail e.t.c.)
    2. Airmail Registered – Tracked shipping via national postal services (HK Post, Singapore Post, China Post, PostNL, Swiss Post, Sweden Post, USPS, Royal Mail e.t.c.)
    3. Expedited Shipping – Express shipping with courier delivery (DHL, UPS, FedEx, TNT)

    Delivery Time

    Airmail and Airmail Registered Area Estimated Delivery Time
    United States, Canada 7-25 business days
    Australia, New Zealand, Singapore, United Arab Emirates 10-25 business days
    United Kingdom, France, Spain, Germany, Netherlands, Japan, Belgium, Denmark, Finland, Ireland, Norway, Portugal, Sweden, Switzerland 10-25 business days
    Italy, Brazil, Russia, South Africa 10-45 business days
    Other countries 10-35 business days
    Expedited Shipping 3-10 business days to Worldwide

    Note: If you choose an expedited shipping, please remember to leave a valid contact number, this is required for expedited shipping’s courier delivery.

  •  Returns & Refund

    Last updated October 05, 2022

    Returns

    If you are not completely satisfied with your purchase for any reason, you may return it to us for a full refund within 15 days from delivery date. All returned items must be in new and unused condition, with all original tags and labels attached.

    Return Process

    To return an item, please email our customer service at sales@alexnld.com to obtain a Return Merchandise Authorization (RMA) number. After receiving a RMA number, place the item securely in its original packaging, and mail your return to the following address:

    Alex NLD
    Attn: Returns
    RMA #
    HaGiborim St 8
    Tiberias, 14388
    Israel

    Please note, you will be responsible for the return shipping charges. We strongly recommend that you use a trackable method to mail your return.

    All customers should contact us and obtain Return Merchandise Authorization (RMA) number before sending anything to us. We will not be responsible for returned item(s) without notifying us in advance.

    Refunds

    After receiving your return and inspecting the condition of your item, we will process your refund to the credit / debit card or PayPal account which was used to place the original order.

    Please allow at least seven (7) days from the receipt of your item to process your refund. Refunds may take 1-2 billing cycles to appear on your credit card statement, depending on your credit card company. We will notify you by email when your refund has been processed.

    Exceptions

    If an item is found damaged or defective on receipt, we kindly ask you to contact us within 15 days from the delivery date to arrange a refund or exchange without physical return of the item.

    Please provide us with following:

    1. Photos of the front and back sides of the packaging box;
    2. A photo, video or screenshot of the defective item or the defective part of the parcel.

    Our customer service team will communicate with you to arrange a refund or reshipment without physical return of the item.

    Warranty & Repair service

    If any of the items you have purchased from us is found defective within 1 year from receipt, you are entitled to a repair under warranty. Please kindly provide us with evidence photos or videos of the defective item. After providing such information to our Customer Service team  and the problem is acknowledged, you can send the items back to us for a repair.

    Note:  Please be aware, we do not cover the cost of the returns fees in  warranty & repair service.

    Order Cancellation

    If you want to cancel an order within 24 hours from confirmation of the payment, you will be entitled to a full refund. It is still possible to cancel an order after 24 hours, provided that it has not yet been shipped. If an order has been shipped, it’s impossible for us to cancel or modify it anymore. If you still want a refund, you required to return the item on it’s arrival.

    Questions

    If you have any questions concerning our return policy, please contact us at:

    +972 054-536-2888
    sales@alexnld.com

     


  Share

Description:

ZK-TD4 is a MOS Switch Controller Trigger Delay Module with Timer and Cycle functions.It can work in 16kind work mode with or without trigger signal.It also can be delay a random time in the set range.Features:

1.16kind work mode2.High Level or PNP signal trigger3.Power-ON trigger4.Button switch trigger5.400W 15A MOS Driver 6.Support parameter memory function7.Support UART communication function8.Optocoupler isolated output9.Support forced stop function10.Support power saving modeParameters:

1.Product Name:ZK-TD4 Trigger Cycle Timer Delay Controller2.Product Number:ZK-TD43.Working Voltage:DC 5.0V~30V4.Trigger Type:Button/PNP/High Level Signal5.Trigger Signal:DC 3.0V~24V6.Output Type:Voltage Output(Same to input voltage)7.Output Power:400W(Max)8.Output Current:15A9.Quiescent Current:20mA10.Display: 3Bit Red LED Display Screen11.Working Temperature range:-40℃~85℃12.Working Humidity Range:5%-95%RH13.Module Size:60*34*12mmTiming range:

1.Continuously adjustable from 0.1 seconds to 999 minutes.2.Enter the settings interface when short press button ‘STOP’ in the parameter modification interface(Flashing) to select timing range.3.Pay attention to the position where the decimal point moves when the button is pressed.4.Display ‘XXX.’ The decimal point is the last bit, the timing range is 1 second ~ 999 seconds.5.Display ‘XX.X’ The decimal point is the second last,Timing range is 0.1 second to 99.9 seconds.

6.Display ‘X.X.X.’ The decimal point is fully lit, timing range is 1 minute to 999 minutes.7.For example, if you want to set the OP to 3.2 seconds, Screen will display ‘03.2’8.OP and CL parameters are the same in different work mode.9.It will display OP(CL,LOP) and corresponding delay time by short press button SET in main display interface.10.It just display OP and corresponding delay time in P1 mode by short press button SET in main display interface.Parameter Description:

1>.OP:Delay time for turn On;2>.CL:Delay time Turn OFF;3>.LOP:Number of cycles.Range is 1-999tims.’—-‘ means unlimited loop.4>.CLL:Minimum value of random delay range. The set range is 0.0~99.9second. This CLL parameter just be used for P15 work mode.5>.CLH:Maximum value of random delay range.The set range is 0.0~99.9second. This CLH parameter just be used for P15 work mode.6>.SP:Set PWM duty cycle. The set range is 20%,25%,30%,35% to 100%.Work Mode:

1.Power-ON Trigger Mode:1.1>.ZK-TD4 will start delay after power on. This mode no need input other trigger signal. The power supply is the trigger signal. 1.2>.P00: Power ON and output keep OFF and start delay time CL. Then turn ON output after delay time CL. E.g. Power ON->OFF->Delay CL->ON.1.3>.P01: Power ON and output turn ON and start delay time OP. Then turn OFF output after delay time OP. E.g. Power ON->ON->Delay OP->OFF.1.4>.P02: Power ON and output turn ON and start delay time OP. Then turn OFF output after delay time OP. Keep OFF for delay time CL. Then turn ON output after delay time OL. And then loops the above action.The number of cycles (LOP) can be set. Output will keep OFF after cycle. E.g. Power ON->ON->Delay OP->OFF->Delay CL->cycles->OFF.1.5>.P03: Power ON and output turn OFF and start delay time CL. Then turn ON output after delay time CL. Keep ON for delay time OP. Then turn OFF output after delay time OP. And then loops the above action.The number of cycles (LOP) can be set. Output will keep ON after cycle. E.g. Power ON->OFF->Delay CL->ON->Delay OP->cycles->ON.2.PNP/High Level Signal Trigger Mode:2.1>.ZK-TD4 will start delay after input trigger. This mode need input trigger signal after provide work power supply.2.2>.P04: Input trigger signal and output turn ON and start delay time OP. Then turn OFF output after delay time OP. Trigger again is invalid during delay.E.g. Trigger->ON->Delay OP->OFF.2.3>.P05: Input trigger signal and output turn ON and start delay time OP. Then turn OFF output after delay time OP. Restart delay OP if trigger again during delay.E.g. Trigger->ON->Delay OP->OFF.2.4>.P06: Input trigger signal and output turn ON and start delay time OP. Then turn OFF output after delay time OP. Stop delay and output turn OFF if trigger again during delay.E.g. Trigger->ON->Delay OP->OFF.2.5>.P07: Input trigger signal and output keep OFF and start delay time CL. Then turn ON output after delay time CL. E.g. Trigger->OFF->Delay CL->ON.2.6>.P08: Input trigger signal and output turn OFF and start delay time CL. Then turn ON output after delay time CL. Keep ON for delay time OP. Then turn OFF output after delay time OP. Trigger again is invalid during delay. E.g. Trigger->OFF->Delay CL->ON->Delay OP->OFF.2.7>.P09: Input trigger signal and output turn OFF and start delay time CL. Then turn ON output after delay time CL. Keep ON for delay time OP. Then turn OFF output after delay time OP. Restart delay OP if trigger again during delay. E.g. Trigger->OFF->Delay CL->ON->Delay OP->OFF.2.8>.P10: Input trigger signal and output turn OFF and start delay time CL. Then turn ON output after delay time CL. Keep ON for delay time OP. Then turn OFF output after delay time OP. And then loops the above action.The number of cycles (LOP) can be set. Output will keep ON after cycle.Stop delay and output turn ON if trigger again during cycles. E.g. Trigger->OFF->Delay CL->ON->Delay OP->cycles->ON.2.9>.P11: Input trigger signal and output turn ON and start delay time OP. Then turn OFF output after delay time OP. Keep OFF for delay time CL. Then turn ON output after delay time CL. And then loops the above action.The number of cycles (LOP) can be set. Output will keep OFF after cycle.Stop delay and output turn OFF if trigger again during cycles. E.g. Trigger->ON->Delay OP->OFF->Delay CL->cycles->OFF.2.10>.P12: Input trigger signal and output turn ON and start delay time OP. Then turn OFF output after delay time OP. Keep OFF for delay time CL. Then turn ON output after delay time CL. And then loops the above action.The number of cycles (LOP) can be set. Output will keep OFF after cycle.Trigger again is invalid during cycles. E.g. Trigger->ON->Delay OP->OFF->Delay CL->cycles->OFF.2.11>.P13: Keep input trigger signal and output turn ON.Then start delay time OP if remove input trigger.Then turn OFF output after delay time OP.Stop delay and output turn ON if trigger again during delay.2.12>.P14: Keep input trigger signal and output turn OFF.Then start delay time CL if remove input trigger.Then turn ON output after delay time CL.Stop delay and output turn OFF if trigger again during delay.3.Random Delay Mode:3.1>.P15: Input trigger signal and output keep OFF and start delay time. The delay time between CLL and CLH. Then turn ON output after delay time CLL~CLH.This mode also can set PWM duty cycle from 20%,25%,30%,35% to 100%. (The delay time is a random value between CLL and CLH. Their setting range is 0.0~99.9second and CLH is more than CLL.) E.g. Trigger->OFF->Delay->ON.Set steps:

1.Confirm the working mode before start to set mode and parameters.2.Keep press SET Button about 2second enter to select work mode.3.Press UP and Down button to switch work mode P00~P015.4.Press SET button to set parameter value for selected work mode such as P03 work mode.5.The first set parameter OP will flashing about 2second and display parameter value.6.Press STOP button to move the decimal point and set delay time range.7.Press UP and Down button to set OP parameter value.8.Press SET button to set the second parameter value CL. Then set time range and parameter value as the same method.9.Press SET button to set the third parameter value LOP. Then set parameter as the same method. Note:’—-’ means unlimited loop.10.For P15 work mode the set method is the same for CLL, CLH and SP. Note: The delay time is 0.0~99.9second at this mode.11.Keep press SET Button about 2second to save parameter and exit set mode to start normal work.Additional Features:

1.Auto sleep function: keep press button ‘STOP’ about 2second in the normal running interface to turn on or off auto sleep function.1.1C-L:Turn ON auto sleep function.Screen will automatically turns off if there is no operation within 3 minutes.It can be wake up by any buttons.1.2.O-d:Turn OFF auto sleep function.

2.Enabled/Disabled output by press button STOP:2.1.ON:Enabled output during delay time OP.2.2.OFF:Disabled output.Module can not output any signal at this mode.Use Steps:

1.Connect right work voltage from input terminal.2.Set work mode and parameter value.3.Remove work power supply.4.Connect Load and trigger signal if need.5.Re connect the power supply.6.Start normal work with or without in trigger signal by selected work mode.Note:

1.It can output voltage.The output voltage is same to input voltage.2.It will display ‘000’ if stop work.It shows the decimal point when working.3.The VIN and OUT+ are connected in the internal circuit.4.The GND and OUT- are not connected in the internal circuit. Users cannot connect GND and OUT- together.Otherwise, module will keep the output.5.Please read use manual and description before use.Application:

1.Delay switching2.Counter3.Access control system4.Car circuit modification5.Motor6.The electromagnetic valve7.Light stripPackage included:

5 x ZK-TD4 Trigger Cycle Timer Delay Controller


Reviews

There are no reviews yet.


Be the first to review “5Pcs ZK-TD4 DC 5V 12V 24V Trigger Cycle Timer Delay Controller Module 15A 400W MOS Control Switch 16-Work Mode”

Your email address will not be published. Required fields are marked *


Q & A

There are no questions yet

Ask a question

Your question will be answered by a store representative or other customers.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Thank you for the question!

Your question has been received and will be answered soon. Please do not submit the same question again.

Error

Warning

An error occurred when saving your question. Please report it to the website administrator. Additional information:

Add an answer

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Thank you for the answer!

Your answer has been received and will be published soon. Please do not submit the same answer again.

Error

Warning

An error occurred when saving your answer. Please report it to the website administrator. Additional information:

Product ID: 11489290 Category:
Close My Cart
Close Wishlist
Close

Close
Navigation
Categories