DC 5V 12V 24V 10A Time Delay Relay Module with Shell 32 Modes LED Digital Timming Trigger Timer Control Switch Pulse Cycle

$17.99
  Availability: In Stock
  Shipping: Free Airmail 
  Estimated Delivery: 

+
  •   Shipping Methods

    Handling Time

    Before we can ship your order, we prepare your products, do strict quality-control tests and carefully package the items. The time it takes to prepare your items for shipping is separate from the delivery time. It usually takes 1-3 business days to ship out .

    Shipping Methods

    You can choose the preferred shipping method on the cart page during the checkout process. We offers 3 international shipping methods:

    1. Airmail – Free untracked economy shipping via national postal services (HK Post, Singapore Post, China Post, PostNL, Swiss Post, Sweden Post, USPS, Royal Mail e.t.c.)
    2. Airmail Registered – Tracked shipping via national postal services (HK Post, Singapore Post, China Post, PostNL, Swiss Post, Sweden Post, USPS, Royal Mail e.t.c.)
    3. Expedited Shipping – Express shipping with courier delivery (DHL, UPS, FedEx, TNT)

    Delivery Time

    Airmail and Airmail Registered Area Estimated Delivery Time
    United States, Canada 7-25 business days
    Australia, New Zealand, Singapore, United Arab Emirates 10-25 business days
    United Kingdom, France, Spain, Germany, Netherlands, Japan, Belgium, Denmark, Finland, Ireland, Norway, Portugal, Sweden, Switzerland 10-25 business days
    Italy, Brazil, Russia, South Africa 10-45 business days
    Other countries 10-35 business days
    Expedited Shipping 3-10 business days to Worldwide

    Note: If you choose an expedited shipping, please remember to leave a valid contact number, this is required for expedited shipping’s courier delivery.

  •  Returns & Refund

    Last updated October 05, 2022

    Returns

    If you are not completely satisfied with your purchase for any reason, you may return it to us for a full refund within 15 days from delivery date. All returned items must be in new and unused condition, with all original tags and labels attached.

    Return Process

    To return an item, please email our customer service at sales@alexnld.com to obtain a Return Merchandise Authorization (RMA) number. After receiving a RMA number, place the item securely in its original packaging, and mail your return to the following address:

    Alex NLD
    Attn: Returns
    RMA #
    HaGiborim St 8
    Tiberias, 14388
    Israel

    Please note, you will be responsible for the return shipping charges. We strongly recommend that you use a trackable method to mail your return.

    All customers should contact us and obtain Return Merchandise Authorization (RMA) number before sending anything to us. We will not be responsible for returned item(s) without notifying us in advance.

    Refunds

    After receiving your return and inspecting the condition of your item, we will process your refund to the credit / debit card or PayPal account which was used to place the original order.

    Please allow at least seven (7) days from the receipt of your item to process your refund. Refunds may take 1-2 billing cycles to appear on your credit card statement, depending on your credit card company. We will notify you by email when your refund has been processed.

    Exceptions

    If an item is found damaged or defective on receipt, we kindly ask you to contact us within 15 days from the delivery date to arrange a refund or exchange without physical return of the item.

    Please provide us with following:

    1. Photos of the front and back sides of the packaging box;
    2. A photo, video or screenshot of the defective item or the defective part of the parcel.

    Our customer service team will communicate with you to arrange a refund or reshipment without physical return of the item.

    Warranty & Repair service

    If any of the items you have purchased from us is found defective within 1 year from receipt, you are entitled to a repair under warranty. Please kindly provide us with evidence photos or videos of the defective item. After providing such information to our Customer Service team  and the problem is acknowledged, you can send the items back to us for a repair.

    Note:  Please be aware, we do not cover the cost of the returns fees in  warranty & repair service.

    Order Cancellation

    If you want to cancel an order within 24 hours from confirmation of the payment, you will be entitled to a full refund. It is still possible to cancel an order after 24 hours, provided that it has not yet been shipped. If an order has been shipped, it’s impossible for us to cancel or modify it anymore. If you still want a refund, you required to return the item on it’s arrival.

    Questions

    If you have any questions concerning our return policy, please contact us at:

    +972 054-536-2888
    sales@alexnld.com

     


  Share
Product introduction:

32 modes pulse delay cycle timing delay high precision programmable optical coupler isolation 5V 12V 24V optional, multi-function relay control module, designed for users with a variety of different needs, using microcontroller as the main control unit, preset 32 ​​kinds of functions ,and users can use the correspond in g specific functions according to the actual needs. Can be applied to pump control, motor control, lamp belt control, solenoid valve control and so on.
1. New upgrade, increasing module functions to 32, meeting more application requirements.
2. The anti-reverse connection function of the power supply prevents the module from being damaged due to the wrong power supply.
3. Timing accuracy to 0.01 seconds timing. 0.1 seconds (min.) to 999 minutes (Min.) Optional.
4. Low power consumption and power saving Settings, you can close the display area.

Product parameters:

Product name: multi-function delay relay
Number of relay V: DC5V/1 2V/24V Optional
Input voltage:
5V Version: DC5V power supply;
12V version: DC12V power supply;
24V version: DC24V power supply
Output load: DC 30V, maximum 10A. Within 250V AC, maximum 5A.
Trigger signal:
5V version (high level: 5V);
12V version (high level: 12V),
24V/ version (high level: 5V) Low level is 0V.
Static current: 20mA
Operating current: 60mA
Operating temperature: -25℃-85℃
Blackout memory: Yes

Warm prompt:

1. Please select the required V number version (according to the above relay identification difference, the base point is 5V, that is, 5V version) to avoid wrong purchase;
2. Relay output is passive contact, without current output, to control the on-off action of a line;
3. Input the triggering voltage strictly according to the selected version.

Key setting:

Press K2 and K3 to change the working mode. After selecting the working mode, press K1 to enter the time setting of A, and Axxx is displayed on the screen. At this time, press K2 and K3 to modify the time parameter of A. After setting the time of A, press K1 to set the time of B, and BXXX is displayed on the screen. At this time, press K2 and K3 to modify the time parameter of B, K2 and K3 to add and subtract 1, long press to add and subtract 1 0 quickly, and press K4 to s et the position of the decimal point. After setting the B time (if the mode has t he parameter of C cycle times), press K1 to set the number of C cycles, and the screen displays Cxxx. At this time, press K2 and K3 to modify the parameter of C cycle times, and press K2 and K3 to add and subtract 1 short and press long t o add and subtract 1 0 quickly. After setting, press K1 for the last time to exit t he setting state and save all parameters.

Table showing the position of the decimal point and its time units:

X. X is in the hundreds place, and the time range is 0.01 to 9.99 seconds The time range of xx. X is 0.1 to 99.9 seconds

XXX has no decimal point, and the time range is 1 to 999 seconds

XXX. The decimal point is in the one place. The time range is 1 to 999 minutes Off display: Press K4 key to close the display when not set. Press again to open it again.Here we need to pay attention to the state of the decimal point, many customers set wrong.


Key setting:

Working mode (32 types):

P-11: Point mode, with signal pull-in, without signal disconnection.

P-12: Self-locking mode, the state of relay is reversed once after each trigger.

P-13: After triggering, the relay pulIs and disconnects after A time delay; Invalid trigger during delay.

P-14: After triggering, the relay pulIs and disconnects after A time delay; Retiming is triggered during the delay.

P-15: After triggering, the relay pulIs and disconnects after A time delay; Accumulative timing is triggered during the delay.

P-16: After triggering, the relay pulIs and disconnects after A time delay; Reset triggered during delay (relay disconnection)

P-17: After triggering, the relay closes during the signal duration, the input signal disappears, and the relay is disconnected after A time delay; During the delay period, the relay will be triggered again to keep pulling, and the timing will stop until the last signal disappears, and the relay will be disconnected after A time delay.

P-18: After power-on, the relay immediately pulIs in then disconnects after A delay of A second; Until the next power (signal line IN+IN- no connection)

P-21: Give the signal, delay A time after the relay suction.

P-22: Give A continuous signal, after more than A time, the relay is closed; Signal lost, relay disconnected.

P-23: loss of A triple A time, relay sucking; Signal on, relay disconnected.

P-24: Give A continuous signal, after more than A time, the relay is closed; The signal disappears for more than A time, and the relay is disconnected.

P-25: Give A continuous signal, after more than A time, the relay is closed; A continuous signal is given again. After A time, the relay is disconnected.

P-26: Give the signal, and disconnect after the relay closes for A time; After the signal disappears, the relay closes again for A second and stops.

P-27: Relay with pulse signal (rising edge or falling edge) is disconnected, and there is no pulse signal. After A time delay, the relay is closed (continuous high level or continuous low level is considered as no pulse).

P-28: After power-on, the relay will be closed after A time delay until the pow er is off. (Signal line IN+IN- no connection)

P-31: After power-on, the relay closes A time and disconnects B time, with an infinite cycle; Power off stop (signal line IN+IN- no connection)

P-32: continuous signal, relay sucking time A, disconnect time B, infinite cycle; The signal disappears, terminating the loop.

P-33: Give the primary signal, the relay closes A time, disconnects B time, infinite loop; Give me one more signal to stop the loop.

P-34: After power-on, delay A time, then the relay pulls on and closes, and disconnects after B time. (Signal line IN+IN- no connection)

P-35: Give A signal, delay A time, the relay is closed, closed B time after disconnect.

P-36: Continuous signal is given. After A time, the relay is closed and disconnected after B time. The signal disappears, the timing is cleared, and the relay is disconnected.

P-37: when there is A signal, the relay will disconnect automatically after pulling off time A, and then tinning time B. Signal triggering is invalid within time A +B.

P-38: there is A signal, the relay will automatically disconnect after A time, an d then time B time, and automatically disconnect after A time.

P-41: No action on signal; Signal loss trigger; The relay disconnects after absorbing and combining delay time A.

P-42: the signal disappears and the relay closes after A time delay; The relay is disconnected after B time delay.

P-43: the signal disappears, and the relay closes after the time of disappearance exceeds A; The relay is disconnected after B time delay.

P-44: After power-on, the relay closes A time and disconnects B time; Relay disconnects and stops after cycle C (signal line IN+IN- no connection)

P-45: Does not operate after being powered on. After the signal is given, the relay closes time A and disconnects time B; After C cycles, the relay disconnects and stops; If the signal is given, it is executed again,

P-46: After feeding the signal for more than A times, the relay is closed; Keep sucking; Power cut off.

P-47: After the signal is given for more than A times, the relay is closed; Disconnect after B time of suction.

P-48: Within time C, after continuous signal feeding for more than A times, the relay will disconnect and stop after time B.


Package included:


1 x Delay Relay Module

1 x Box(optional)

Reviews

There are no reviews yet.


Be the first to review “DC 5V 12V 24V 10A Time Delay Relay Module with Shell 32 Modes LED Digital Timming Trigger Timer Control Switch Pulse Cycle”

Your email address will not be published. Required fields are marked *


Q & A

There are no questions yet

Ask a question

Your question will be answered by a store representative or other customers.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Thank you for the question!

Your question has been received and will be answered soon. Please do not submit the same question again.

Error

Warning

An error occurred when saving your question. Please report it to the website administrator. Additional information:

Add an answer

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Thank you for the answer!

Your answer has been received and will be published soon. Please do not submit the same answer again.

Error

Warning

An error occurred when saving your answer. Please report it to the website administrator. Additional information:

Product ID: 11381369 Category: Voltage: 12V No box (+5 more)