Module parameter:
Wide voltage power supply 5.0V–60V;
One mode can set multiple time periods, up to 5 time periods;
With buzzer alarm function.
Mode introduction:
OPE: Relay closing time CLE: Relay opening time
Time period: PE-1 to PE-5, 5 time periods
‘—-‘: function shield
P-1: Every day OPE relay is closed/output pulse CLE relay is disconnected/output pulse
P-2: OPE relay closed/pulse output on the same day CLE relay disconnected/pulse output
P-3: What day of the month and day: OPE relay closed/output pulse CLE relay disconnected/output pulse
P-4: From what day of the month to what day of the month, what time every day starts and ends at what time: OPE relay is closed/output pulse CLE relay is disconnected/output pulse
P-5: From what day of the month to what day of the day, what time starts and ends at what time: OPE relay is closed/output pulse CLE relay is disconnected/output pulse
Note: Stop time/date (CLE)> start time/date (OPE)
In the time to run the interface, press the DOWN button for a while:
Step 1: Select the time period: PE-1 ~ PE-5 Press UP and DOWN to select;
Step 2: Press the SET key to select the mode: P-1 ~ P-5 (Set this time period to the corresponding mode) by pressing the UP and DOWN keys.
(‘—-‘ means to block this time period)
Note: Each time period can be repeated from the ‘—-‘, P-1 ~ P-5 one of the optional; For example,you can let five time periods at the same time work in the P-1 mode, or let Time period 1 work in P-1 mode, time period 2 work in P-2 mode and so on.
Step 3: After the mode selection is finished, press the SET key to enter the time period setting interface, set the interface in the time period, press the SET key to switch the parameter, ‘OPE’ start time point, ‘CLE’ end point, ‘dAE’ date information;
Step 4: After setting the parameters to exit the settings, press the SET button for 2 seconds to release, automatically check whether the parameter settings are legal, legal to save the parameters, return to the time to run the interface; if the parameter is wrong, ‘ERR’ reminder (for example, stop time or Date <= start time or date), return to the parameter setting interface;
Additional features: Each ‘time period’ can be set individually
In the specific parameter setting interface (after the second step), press the STOP button to switch the output mode:
OUT1: Start time point turns on the relay, the end time is off the relay
OUT2: Outputs 1S pulse to start or end time
In the specific parameter setting interface (after the second step), press the STOP button for a while to switch the ringing mode:
BLL0: Ring disable
BLL1: Ring enable
Note: When the bell rings, press any button to stop the ring
STOP key function expansion:
Relay enable mode:
1. ON: enable relay on;
2. OFF: Do not turn on the relay, it is always off;
Press the STOP button on the time display interface to switch between ON
and OFF, the current status will flash, and then return to the main interface. (This function is the emergency stop function, press once to close the closed relay) After the relay is disabled, the product can be used as an alarm clock.
Sleep mode:
1. C-P sleep mode: within five minutes, without any operation, the digital tube automatically shut down the display, the program normal operation;
2. O-d normal mode: digital tube is always open display;
Press the STOP button for a while after 2 seconds to release, to achieve
C-P and O-d state of the switch, the current state will flash, and then return to the main interface.
Package included:
1 x Real-time relay Module