ETCR2900 On-Line Monitoring Ground Resistance Meter 0.01-2000 AC 0~600V Online Earth Resistance Tester

$245.39
  Availability: In Stock
  Shipping: Free Airmail 
  Estimated Delivery: 
   Bulk Savings (Buy more save more)
+
  •   Shipping Methods

    Handling Time

    Before we can ship your order, we prepare your products, do strict quality-control tests and carefully package the items. The time it takes to prepare your items for shipping is separate from the delivery time. It usually takes 1-3 business days to ship out .

    Shipping Methods

    You can choose the preferred shipping method on the cart page during the checkout process. We offers 3 international shipping methods:

    1. Airmail – Free untracked economy shipping via national postal services (HK Post, Singapore Post, China Post, PostNL, Swiss Post, Sweden Post, USPS, Royal Mail e.t.c.)
    2. Airmail Registered – Tracked shipping via national postal services (HK Post, Singapore Post, China Post, PostNL, Swiss Post, Sweden Post, USPS, Royal Mail e.t.c.)
    3. Expedited Shipping – Express shipping with courier delivery (DHL, UPS, FedEx, TNT)

    Delivery Time

    Airmail and Airmail Registered Area Estimated Delivery Time
    United States, Canada 7-25 business days
    Australia, New Zealand, Singapore, United Arab Emirates 10-25 business days
    United Kingdom, France, Spain, Germany, Netherlands, Japan, Belgium, Denmark, Finland, Ireland, Norway, Portugal, Sweden, Switzerland 10-25 business days
    Italy, Brazil, Russia, South Africa 10-45 business days
    Other countries 10-35 business days
    Expedited Shipping 3-10 business days to Worldwide

    Note: If you choose an expedited shipping, please remember to leave a valid contact number, this is required for expedited shipping’s courier delivery.

  •  Returns & Refund

    Last updated October 05, 2022

    Returns

    If you are not completely satisfied with your purchase for any reason, you may return it to us for a full refund within 15 days from delivery date. All returned items must be in new and unused condition, with all original tags and labels attached.

    Return Process

    To return an item, please email our customer service at sales@alexnld.com to obtain a Return Merchandise Authorization (RMA) number. After receiving a RMA number, place the item securely in its original packaging, and mail your return to the following address:

    Alex NLD
    Attn: Returns
    RMA #
    HaGiborim St 8
    Tiberias, 14388
    Israel

    Please note, you will be responsible for the return shipping charges. We strongly recommend that you use a trackable method to mail your return.

    All customers should contact us and obtain Return Merchandise Authorization (RMA) number before sending anything to us. We will not be responsible for returned item(s) without notifying us in advance.

    Refunds

    After receiving your return and inspecting the condition of your item, we will process your refund to the credit / debit card or PayPal account which was used to place the original order.

    Please allow at least seven (7) days from the receipt of your item to process your refund. Refunds may take 1-2 billing cycles to appear on your credit card statement, depending on your credit card company. We will notify you by email when your refund has been processed.

    Exceptions

    If an item is found damaged or defective on receipt, we kindly ask you to contact us within 15 days from the delivery date to arrange a refund or exchange without physical return of the item.

    Please provide us with following:

    1. Photos of the front and back sides of the packaging box;
    2. A photo, video or screenshot of the defective item or the defective part of the parcel.

    Our customer service team will communicate with you to arrange a refund or reshipment without physical return of the item.

    Warranty & Repair service

    If any of the items you have purchased from us is found defective within 1 year from receipt, you are entitled to a repair under warranty. Please kindly provide us with evidence photos or videos of the defective item. After providing such information to our Customer Service team  and the problem is acknowledged, you can send the items back to us for a repair.

    Note:  Please be aware, we do not cover the cost of the returns fees in  warranty & repair service.

    Order Cancellation

    If you want to cancel an order within 24 hours from confirmation of the payment, you will be entitled to a full refund. It is still possible to cancel an order after 24 hours, provided that it has not yet been shipped. If an order has been shipped, it’s impossible for us to cancel or modify it anymore. If you still want a refund, you required to return the item on it’s arrival.

    Questions

    If you have any questions concerning our return policy, please contact us at:

    +972 054-536-2888
    sales@alexnld.com

     


  Share
Description:

ETCR2900 Online Earth Resistance Tester composed of the detector and the monitoring software. The large LCD display of the detector is very intuitive. Setting the alarm thresholds and audible and visible alarm indicator are available. The material of the shell has the characteristic of resistance to high low temperature, corrosion prevention, inflaming retarding etc, ensure high-accuracy, high stability and high reliability of long time on-line monitoring outdoors, underground mine and indoors. The monitor software can real-time display the values of measured ground resistance and voltage. The user also can set the automatic monitoring interval time by the detector or the monitor software, the range of interval time is 1-999 hours. The automatic recording data can be generated reports, it is convenient to preservation, historical data query, print, analysis.

ETCR2900 Online Earth Resistance Tester apply to transmission line tower grounding, underground mine equipment grounding, meteorological fulmination proof grounding, petrochemical grounding, communication grounding, distribution substation grounding, railway equipment grounding, building warehouse grounding, electrical equipment grounding etc.

Specifications:

Function
On-line monitoring ground resistance, ground voltage, equipotential connection resistance, low resistance.
Power Supply
Standard: 12V±1VDC, 150mA Max.
Optional: 24V±1VDC.
 
Range
Accuracy
Resolution
Resistance
0.01Ω~20Ω
±2%rdg±3dgt
(auxiliary ground resistance 100Ω±5%, voltage to ground<10V)
0.01Ω
0.1Ω~200Ω
0.1Ω
1Ω~2000Ω
Voltage
0~600V AC
±2%rdg±3dgt
1V
Measure Mode
Precise 3-wire measurement, simple 2-wire measurement.
Measure Method
Ground resistance: rated current change-pole method, measured current 3mA Max, 820Hz;
Voltage to ground: average value rectification method.
Data Mode
Mean.
Display Mode
4-digital super-large LCD.
Measuring Indicator
During measurement, LCD count down display.
LCD Size
128mm×75mm;
Display field: 124mm×67mm.
Dimension
L×W×H: 190mm×117mm×54mm.
Measure Rate
Voltage to ground: about 2 times/second; ground resistance: about 30 seconds/time.
Measure Times
Over 10000 times
Line Voltage
Measuring voltage to ground: measuring below AC 600V.
Instrument Interface
Pluggable terminal blocks: 9 pin connector.
Communication Method
RS485 (or optional RS232).
Communication Line
USB to RS485 communication line( or optionalUSB to RS232 communication line).
Range Shift
Automatically.
Data Storage
400 sets, flash display FULL icon to indicate storage is full.
Interval Time
Range of automatic monitoring interval time: 1-999 h.
Data Access
Data read function: READ icon display.
Overflow Display
Exceeding measuring range overflow function: OL icon display.
Power Consumption
Standby: 25mA Max.
Measurement: 400mA Max.
Alarm
Audible and visible alarm.
Power supply Voltage
When power supply voltage decreases to about 7.8V, will display, reminding to replace the power.
Weight
Detector: 450g.
Working Humiture
-10°C~40°C; below 80%rh.
Storage Humiture
– -20°C~60°C; below 70%rh.
Overload Protection
Measurement ground resistance: E-P, E-C between each interfaces AC 280V/3 sec.
Insulation Value
Over 10MΩ(between circuit and enclosure 500V).
Withstand Voltage
AC 3700V/rms. (Between circuit and enclosure).
Electromagnetism
IEC61010-4-3,Radio frequency electromagnetic field≤1V/m.
Applicable Safety Rules
IEC61010-1, IEC1010-2-31, IEC61557-1,5, IEC60529(IP54), Pollution degree 2, CAT III 300V.

Package Included:

1 x Resistance Tester

Details Picture:


Reviews

There are no reviews yet.


Be the first to review “ETCR2900 On-Line Monitoring Ground Resistance Meter 0.01-2000 AC 0~600V Online Earth Resistance Tester”

Your email address will not be published. Required fields are marked *


Q & A

There are no questions yet

Ask a question

Your question will be answered by a store representative or other customers.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Thank you for the question!

Your question has been received and will be answered soon. Please do not submit the same question again.

Error

Warning

An error occurred when saving your question. Please report it to the website administrator. Additional information:

Add an answer

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Thank you for the answer!

Your answer has been received and will be published soon. Please do not submit the same answer again.

Error

Warning

An error occurred when saving your answer. Please report it to the website administrator. Additional information:

Product ID: 14200683 Category:
Close My Cart
Close Wishlist
Close

Close
Navigation