Handheld Portable Dual-channel VI Curve Tester Circuit Board Online Detection ASA Tester 4 Gear Frequency Alternating Speed Adjustable

$67.59
  Availability: In Stock
  Shipping: Free Airmail 
  Estimated Delivery: 
   Bulk Savings (Buy more save more)
+
  •   Shipping Methods

    Handling Time

    Before we can ship your order, we prepare your products, do strict quality-control tests and carefully package the items. The time it takes to prepare your items for shipping is separate from the delivery time. It usually takes 1-3 business days to ship out .

    Shipping Methods

    You can choose the preferred shipping method on the cart page during the checkout process. We offers 3 international shipping methods:

    1. Airmail – Free untracked economy shipping via national postal services (HK Post, Singapore Post, China Post, PostNL, Swiss Post, Sweden Post, USPS, Royal Mail e.t.c.)
    2. Airmail Registered – Tracked shipping via national postal services (HK Post, Singapore Post, China Post, PostNL, Swiss Post, Sweden Post, USPS, Royal Mail e.t.c.)
    3. Expedited Shipping – Express shipping with courier delivery (DHL, UPS, FedEx, TNT)

    Delivery Time

    Airmail and Airmail Registered Area Estimated Delivery Time
    United States, Canada 7-25 business days
    Australia, New Zealand, Singapore, United Arab Emirates 10-25 business days
    United Kingdom, France, Spain, Germany, Netherlands, Japan, Belgium, Denmark, Finland, Ireland, Norway, Portugal, Sweden, Switzerland 10-25 business days
    Italy, Brazil, Russia, South Africa 10-45 business days
    Other countries 10-35 business days
    Expedited Shipping 3-10 business days to Worldwide

    Note: If you choose an expedited shipping, please remember to leave a valid contact number, this is required for expedited shipping’s courier delivery.

  •  Returns & Refund

    Last updated October 05, 2022

    Returns

    If you are not completely satisfied with your purchase for any reason, you may return it to us for a full refund within 15 days from delivery date. All returned items must be in new and unused condition, with all original tags and labels attached.

    Return Process

    To return an item, please email our customer service at sales@alexnld.com to obtain a Return Merchandise Authorization (RMA) number. After receiving a RMA number, place the item securely in its original packaging, and mail your return to the following address:

    Alex NLD
    Attn: Returns
    RMA #
    HaGiborim St 8
    Tiberias, 14388
    Israel

    Please note, you will be responsible for the return shipping charges. We strongly recommend that you use a trackable method to mail your return.

    All customers should contact us and obtain Return Merchandise Authorization (RMA) number before sending anything to us. We will not be responsible for returned item(s) without notifying us in advance.

    Refunds

    After receiving your return and inspecting the condition of your item, we will process your refund to the credit / debit card or PayPal account which was used to place the original order.

    Please allow at least seven (7) days from the receipt of your item to process your refund. Refunds may take 1-2 billing cycles to appear on your credit card statement, depending on your credit card company. We will notify you by email when your refund has been processed.

    Exceptions

    If an item is found damaged or defective on receipt, we kindly ask you to contact us within 15 days from the delivery date to arrange a refund or exchange without physical return of the item.

    Please provide us with following:

    1. Photos of the front and back sides of the packaging box;
    2. A photo, video or screenshot of the defective item or the defective part of the parcel.

    Our customer service team will communicate with you to arrange a refund or reshipment without physical return of the item.

    Warranty & Repair service

    If any of the items you have purchased from us is found defective within 1 year from receipt, you are entitled to a repair under warranty. Please kindly provide us with evidence photos or videos of the defective item. After providing such information to our Customer Service team  and the problem is acknowledged, you can send the items back to us for a repair.

    Note:  Please be aware, we do not cover the cost of the returns fees in  warranty & repair service.

    Order Cancellation

    If you want to cancel an order within 24 hours from confirmation of the payment, you will be entitled to a full refund. It is still possible to cancel an order after 24 hours, provided that it has not yet been shipped. If an order has been shipped, it’s impossible for us to cancel or modify it anymore. If you still want a refund, you required to return the item on it’s arrival.

    Questions

    If you have any questions concerning our return policy, please contact us at:

    +972 054-536-2888
    sales@alexnld.com

     


  Share
Features:

4 test frequencies, can be used when connected to an oscilloscope, both analogs oscilloscopes and digital oscilloscopes can be used.
Dual signal input, alternating display function allows you to use it in easier.
4-gear frequency, alternating speed adjustable, you can adjust it according to your needs.
One click on singles channel/alternating display, which can give you a better using experience.
When testing the circuit board online, do not recharge the circuit board. If there is a large capacitor on the circuit board, discharge the capacitor first, otherwise it is easy to burn out the VI test board.

Specifications:

Material: plastics
Channel: 2 channels
Frequency: 4 gears
Package size: 195 * 135 * 105mm / 7.7 * 5.3 * 4.1in
Package weight: 435g / 1.0lb

Oscilloscope parameter setting:

1. Adjust the oscilloscope to X-Y mode (different oscilloscopes have different adjustment methods, please explore by yourself)
2. Adjust the vertical parameters of the 2 channels of X Y to 1V/div, and only one of the single-track oscilloscopes needs to be adjusted. 
3. The analog oscilloscope does not need to adjust the time base, the digital oscilloscope time base is adjusted between 1-5ms
4. After the connection is correct, the oscilloscope will display a horizontal line. If a vertical line is displayed, the xY plug will be reversed.
5. Adjust the vertical and horizontal parameters, the horizontal and vertical lines are in the display box.

Method of connecting analog oscilloscope:

1. The analog oscilloscope connection is relatively simple, and different oscilloscopes are slightly different.
2. Adjust the oscilloscope to xY mode. Some oscilloscopes can be selected by pressing the buttons, while others are selected by the knob to xY mode. Please study by yourself.
3. Connect the BNC cable to the oscilloscope and power on. Normally, a horizontal line will be displayed. Adjust the xY vertical channel parameters, about 1V/div, and then adjust the x Y attenuation so that the horizontal line is in the display frame. It can also pass the VI test version. The x attenuation potentiometer on the upper side can assist in adjusting the length of the horizontal line. If the test pen iis short-circuited, a vertical line will be displayed under normal circumstances. If the vertical line is too long or too short, you need to adjust the Y channel parameters to make the vertical line in the display frame. Half grid or 1 grid to the edge is better. If the horizontal and vertical lines are normal, you can enter the normal measurement.

How to connect a digital oscilloscope:

For digital oscilloscopes, enter the xY mode through the menu or keys. The two channels of xY are adjusted to 1V/div, and the single-track oscilloscope only needs to adjust the Y channel. Adjust the time base to 1-5 milliseconds. The xY channel selects DC coupling, and the attenuation is 1x.

When the oscilloscope is not connected, the screen should be a bright spot. Adjust the horizontal and vertical to center the bright spot. Connect the VI tester. Normally, it should be a horizontal line. Adjust the 103 potentiometer at the top of the VI board to make the horizontal line in the display frame. , Half a grid or 1 grid to the edge is better. Short-circuit the test leads, and the display should be a vertical line at this time. Adjust the Y channel parameters so that the vertical line is in the display frame. So far, debugging is basically over.

When testing the circuit board online, do not charge the circuit board. If there is a large capacitor on the circuit board, discharge the capacitor first, otherwise it is easy to burn out the VI test board.

Package included:

1 x Tester
1 Pair of BNC cable
1 Pair of test cable

Reviews

There are no reviews yet.


Be the first to review “Handheld Portable Dual-channel VI Curve Tester Circuit Board Online Detection ASA Tester 4 Gear Frequency Alternating Speed Adjustable”

Your email address will not be published. Required fields are marked *


Q & A

There are no questions yet

Ask a question

Your question will be answered by a store representative or other customers.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Thank you for the question!

Your question has been received and will be answered soon. Please do not submit the same question again.

Error

Warning

An error occurred when saving your question. Please report it to the website administrator. Additional information:

Add an answer

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Thank you for the answer!

Your answer has been received and will be published soon. Please do not submit the same answer again.

Error

Warning

An error occurred when saving your answer. Please report it to the website administrator. Additional information:

Product ID: 15507426 Category:
Close My Cart
Close Wishlist
Close

Close
Navigation