Oscilloscope Production Kit STC8 LCD Screen Mini Oscilloscope Electronic DIY Kit Parts Electronic Welding

$25.99
  Availability: In Stock
  Shipping: Free Airmail 
  Estimated Delivery: 
   Bulk Savings (Buy more save more)
+
  •   Shipping Methods

    Handling Time

    Before we can ship your order, we prepare your products, do strict quality-control tests and carefully package the items. The time it takes to prepare your items for shipping is separate from the delivery time. It usually takes 1-3 business days to ship out .

    Shipping Methods

    You can choose the preferred shipping method on the cart page during the checkout process. We offers 3 international shipping methods:

    1. Airmail – Free untracked economy shipping via national postal services (HK Post, Singapore Post, China Post, PostNL, Swiss Post, Sweden Post, USPS, Royal Mail e.t.c.)
    2. Airmail Registered – Tracked shipping via national postal services (HK Post, Singapore Post, China Post, PostNL, Swiss Post, Sweden Post, USPS, Royal Mail e.t.c.)
    3. Expedited Shipping – Express shipping with courier delivery (DHL, UPS, FedEx, TNT)

    Delivery Time

    Airmail and Airmail Registered Area Estimated Delivery Time
    United States, Canada 7-25 business days
    Australia, New Zealand, Singapore, United Arab Emirates 10-25 business days
    United Kingdom, France, Spain, Germany, Netherlands, Japan, Belgium, Denmark, Finland, Ireland, Norway, Portugal, Sweden, Switzerland 10-25 business days
    Italy, Brazil, Russia, South Africa 10-45 business days
    Other countries 10-35 business days
    Expedited Shipping 3-10 business days to Worldwide

    Note: If you choose an expedited shipping, please remember to leave a valid contact number, this is required for expedited shipping’s courier delivery.

  •  Returns & Refund

    Last updated October 05, 2022

    Returns

    If you are not completely satisfied with your purchase for any reason, you may return it to us for a full refund within 15 days from delivery date. All returned items must be in new and unused condition, with all original tags and labels attached.

    Return Process

    To return an item, please email our customer service at sales@alexnld.com to obtain a Return Merchandise Authorization (RMA) number. After receiving a RMA number, place the item securely in its original packaging, and mail your return to the following address:

    Alex NLD
    Attn: Returns
    RMA #
    HaGiborim St 8
    Tiberias, 14388
    Israel

    Please note, you will be responsible for the return shipping charges. We strongly recommend that you use a trackable method to mail your return.

    All customers should contact us and obtain Return Merchandise Authorization (RMA) number before sending anything to us. We will not be responsible for returned item(s) without notifying us in advance.

    Refunds

    After receiving your return and inspecting the condition of your item, we will process your refund to the credit / debit card or PayPal account which was used to place the original order.

    Please allow at least seven (7) days from the receipt of your item to process your refund. Refunds may take 1-2 billing cycles to appear on your credit card statement, depending on your credit card company. We will notify you by email when your refund has been processed.

    Exceptions

    If an item is found damaged or defective on receipt, we kindly ask you to contact us within 15 days from the delivery date to arrange a refund or exchange without physical return of the item.

    Please provide us with following:

    1. Photos of the front and back sides of the packaging box;
    2. A photo, video or screenshot of the defective item or the defective part of the parcel.

    Our customer service team will communicate with you to arrange a refund or reshipment without physical return of the item.

    Warranty & Repair service

    If any of the items you have purchased from us is found defective within 1 year from receipt, you are entitled to a repair under warranty. Please kindly provide us with evidence photos or videos of the defective item. After providing such information to our Customer Service team  and the problem is acknowledged, you can send the items back to us for a repair.

    Note:  Please be aware, we do not cover the cost of the returns fees in  warranty & repair service.

    Order Cancellation

    If you want to cancel an order within 24 hours from confirmation of the payment, you will be entitled to a full refund. It is still possible to cancel an order after 24 hours, provided that it has not yet been shipped. If an order has been shipped, it’s impossible for us to cancel or modify it anymore. If you still want a refund, you required to return the item on it’s arrival.

    Questions

    If you have any questions concerning our return policy, please contact us at:

    +972 054-536-2888
    sales@alexnld.com

     


  Share

>>>Manual: Click here to open<<<


Parameter:


Input voltage: DC 3.7-5V
Appearance size: 57*35mm
Weight: 25g

Specification:


MCU: STC8AK64S4A12 27MHz
Controller: an EC11 encoder
Input: single channel
Sec/div: 500ms, 200ms, 100ms, 50ms, 20ms, 10ms, 5ms, 2ms, 1ms, 500us, 200us, 100us (100us is only available in auto trigger mode)
Voltage range: 0-30V


Main interface parameters:
Frequency: 500ms, 200ms, 100ms, 50ms, 20ms, 10ms, 5ms, 2ms, 1ms, 500us, 200us, 100us (100us is only available in auto trigger mode)
Voltage range: 0-30V
Trigger level: trigger voltage level
Trigger slope: rising edge, falling edge trigger
Trigger mode: A-automatic mode, N-normal mode, S-single mode
Main interface status:
run: sampling run
stop: sampling stop
fail: In the automatic trigger mode, the trigger level of the waveform is exceeded
Auto: Uterine voltage range


Parameter setting interface:
PMode (drawing mode): display the waveform with vector active points
LSB: sampling coefficient. Calibrate the sampling voltage by adjusting the LSB
100 times voltage division
BRT (brightness): adjust OLED brightness (25 levels)
FreqPwm (PWM wave frequency): 100HZ-10KHZ
Duty: 1%-99%
operating:
All operations are completed by the EC11 encoder. Inputs include single click, double click, long press, rotation, and rotation while pressing.

Main interface-parameter mode:
Click encoder: run/stop sampling
Double-click the encoder: enter Wave Scroll mode
Rotary encoder: adjust parameters
Press the rotary encoder at the same time: switch between switch options
Automatic and manual range switching: continuously rotate the encoder clockwise to enter the automatic range. Rotate the encoder counterclockwise to enter the manual range.

Main interface-wave scroll mode:
Click encoder: run/stop sampling
Double-click the encoder: enter parameter mode
Long press the encoder: enter the setting interface
Rotary encoder: scroll the waveform horizontally (only available when sampling is stopped)
Rotary encoder when pressed: scroll the waveform vertically (only available when sampling is stopped)

Set interface
Click encoder: N/A
Double-click the encoder: N/A
Long press the encoder: return to the main interface
Rotary encoder: adjust parameters
Rotary encoder when pressed: switch between switch options

Function: Trigger level: For repetitive signals, the trigger level can make it display stably. For single-shot signals, the trigger level can be captured.
Trigger slope: The trigger slope determines whether the trigger point is on the rising or falling edge of the signal.


Trigger mode:
Automatic mode: continuous scanning. Click the encoder to stop or run sampling. If triggered, the waveform will be displayed on the display and the trigger position will be placed in the center of the graph. Otherwise, the waveform will scroll irregularly and display fail.
Normal mode:
After the pre-sampling is completed, the signal can be input. If triggered, the waveform is displayed on the display, waiting for a new trigger. If there is no new trigger, the waveform will be retained.
Single mode: After pre-sampling is completed, a signal can be input. If triggered, the waveform is displayed and sampling stops. The user needs a single point encoder to start the next sample.
In normal mode and single mode, confirm that the trigger level has been adjusted correctly, otherwise the waveform will not be displayed on the display.
Indicator light: Usually the indicator light is on to indicate that sampling is in progress.
Save settings: When exiting the setting interface, all the parameters of the setting interface and the main interface will be saved in EEPROM.


Package included:


1 x Oscilloscope Production Kit

Reviews

There are no reviews yet.


Be the first to review “Oscilloscope Production Kit STC8 LCD Screen Mini Oscilloscope Electronic DIY Kit Parts Electronic Welding”

Your email address will not be published. Required fields are marked *


Q & A

There are no questions yet

Ask a question

Your question will be answered by a store representative or other customers.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Thank you for the question!

Your question has been received and will be answered soon. Please do not submit the same question again.

Error

Warning

An error occurred when saving your question. Please report it to the website administrator. Additional information:

Add an answer

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Thank you for the answer!

Your answer has been received and will be published soon. Please do not submit the same answer again.

Error

Warning

An error occurred when saving your answer. Please report it to the website administrator. Additional information:

Product ID: 11373539 Category:
Close My Cart
Close Wishlist
Close

Close
Navigation
Categories