AC 220V 5A Current Detection Module Current Transformer Protection Board Current Transformer Sensor Module

$20.99
  Availability: In Stock
  Shipping: Free Airmail 
  Estimated Delivery: 

+
  •   Shipping Methods

    Handling Time

    Before we can ship your order, we prepare your products, do strict quality-control tests and carefully package the items. The time it takes to prepare your items for shipping is separate from the delivery time. It usually takes 1-3 business days to ship out .

    Shipping Methods

    You can choose the preferred shipping method on the cart page during the checkout process. We offers 3 international shipping methods:

    1. Airmail – Free untracked economy shipping via national postal services (HK Post, Singapore Post, China Post, PostNL, Swiss Post, Sweden Post, USPS, Royal Mail e.t.c.)
    2. Airmail Registered – Tracked shipping via national postal services (HK Post, Singapore Post, China Post, PostNL, Swiss Post, Sweden Post, USPS, Royal Mail e.t.c.)
    3. Expedited Shipping – Express shipping with courier delivery (DHL, UPS, FedEx, TNT)

    Delivery Time

    Airmail and Airmail Registered Area Estimated Delivery Time
    United States, Canada 7-25 business days
    Australia, New Zealand, Singapore, United Arab Emirates 10-25 business days
    United Kingdom, France, Spain, Germany, Netherlands, Japan, Belgium, Denmark, Finland, Ireland, Norway, Portugal, Sweden, Switzerland 10-25 business days
    Italy, Brazil, Russia, South Africa 10-45 business days
    Other countries 10-35 business days
    Expedited Shipping 3-10 business days to Worldwide

    Note: If you choose an expedited shipping, please remember to leave a valid contact number, this is required for expedited shipping’s courier delivery.

  •  Returns & Refund

    Last updated October 05, 2022

    Returns

    If you are not completely satisfied with your purchase for any reason, you may return it to us for a full refund within 15 days from delivery date. All returned items must be in new and unused condition, with all original tags and labels attached.

    Return Process

    To return an item, please email our customer service at sales@alexnld.com to obtain a Return Merchandise Authorization (RMA) number. After receiving a RMA number, place the item securely in its original packaging, and mail your return to the following address:

    Alex NLD
    Attn: Returns
    RMA #
    HaGiborim St 8
    Tiberias, 14388
    Israel

    Please note, you will be responsible for the return shipping charges. We strongly recommend that you use a trackable method to mail your return.

    All customers should contact us and obtain Return Merchandise Authorization (RMA) number before sending anything to us. We will not be responsible for returned item(s) without notifying us in advance.

    Refunds

    After receiving your return and inspecting the condition of your item, we will process your refund to the credit / debit card or PayPal account which was used to place the original order.

    Please allow at least seven (7) days from the receipt of your item to process your refund. Refunds may take 1-2 billing cycles to appear on your credit card statement, depending on your credit card company. We will notify you by email when your refund has been processed.

    Exceptions

    If an item is found damaged or defective on receipt, we kindly ask you to contact us within 15 days from the delivery date to arrange a refund or exchange without physical return of the item.

    Please provide us with following:

    1. Photos of the front and back sides of the packaging box;
    2. A photo, video or screenshot of the defective item or the defective part of the parcel.

    Our customer service team will communicate with you to arrange a refund or reshipment without physical return of the item.

    Warranty & Repair service

    If any of the items you have purchased from us is found defective within 1 year from receipt, you are entitled to a repair under warranty. Please kindly provide us with evidence photos or videos of the defective item. After providing such information to our Customer Service team  and the problem is acknowledged, you can send the items back to us for a repair.

    Note:  Please be aware, we do not cover the cost of the returns fees in  warranty & repair service.

    Order Cancellation

    If you want to cancel an order within 24 hours from confirmation of the payment, you will be entitled to a full refund. It is still possible to cancel an order after 24 hours, provided that it has not yet been shipped. If an order has been shipped, it’s impossible for us to cancel or modify it anymore. If you still want a refund, you required to return the item on it’s arrival.

    Questions

    If you have any questions concerning our return policy, please contact us at:

    +972 054-536-2888
    sales@alexnld.com

     


  Share
Descriptions:
 
The current transformer is an instrument that converts the primary side large current into the secondary side small current according to the principle of electromagnetic induction.
User can set two current thresholds. When the current is in different range, the module makes corresponding actions and controls the load.
 
Features:
 
1. Support multiple working modes;
2. Support setting the current upper limit;
3. Support setting the current lower limit;
4. Support setting output startup value;
5. Support setting output stop value;
6. Support NC and NO output;
7. High sensitivity;
8. Low power consumption;
9. Support over current control;
10. Digital tube display;
11. High precision;
12. Support power-off memory function;
13. Work output LED indicator.
 
Specifications:
 
Product Name:AC 220V 5A Current Detection Module
Working Voltage:DC 5V/12V/24V(Optional)
Measured Load Voltage:AC 220V
Measured Load Current:0~5A
Measured Current Accuracy:0.01A
Controlled Load Voltage:AC 250V or DC 30V
Controlled Load Current:10A
Stand-by Current:15mA
Working Temperature range:-40℃~85℃
Working Humidity range:0%-95%RH
Size: 66x41x25 mm
 
Button/Screen Description:
 
1. Display will display current measured current as ‘00.00’ when power on or normal display status.Unit is ampere.
2. Screen will display mode such as ‘P-21’ at set mode.
2.1. ’P’ will flashing at set mode.
2.2. The second bit is ‘-’ which is a separator and user can be ignored and no meaning.
2.3. The third bit like ‘2’ is mode select.It can be 1~5.User can adjust mode by button ‘K2’.
2.4. The fourth bit like ‘1’ is function select.It can be 1~2.User can adjust function by button ‘K3’.
3. K1:Set Mode and set Current Lower/Upper Limit Value.
3.1. User need keep press for more than 1second when press K1 for the first time when enter into set mode.It is used to prevent false triggering;
3.2. At the first press K1.It is menu to set mode and select by button K2 and K3;
3.3. At the second press K1.Screen will flashing and display like ‘00.05’.It is menu to set the current lower limit value L1.It means threshold L1 is 0.05A.Press button K2 to increase threshold L1 and K3 to decrease threshold L1.
3.4. At the third press K1.Screen will flashing and display like ‘00.10’.It is menu to set the current upper limit value L2.It means threshold L2 is 0.10A.Press button K2 to increase threshold L2 and K3 to decrease threshold L2.
3.5. At the fourth press K1.It will return to normal display current measured current.Indicates that it is in standby mode.
4. K2:Set mode and increase threshold value.
5. K3:Set mode and error calibration.
5.1. Set mode and increase threshold value at Set Mode.
5.2. Press button K3 in standby mode.It is used to zero adjustment and error calibration.
6. K4:Reserved button.
7. Set parameters will save in standby mode if power off.
 
Function:
 
1>.L1:The current lower limit.
2>.L2:The current upper limit.
3>.L1
4>.Relay default OFF.
5>.P-11:Relay ON when the Measured Current is higher than L1;Relay OFF when the Measured Current is lower than L1 again.
6>.P-12:Relay ON when the Measured Current is higher than L1;Relay will keep ON no matter what the Measured Current is after relay turn on.Relay OFF if re-start power supply.
7>.P-21:Relay ON when the Measured Current is higher than L2;Relay OFF when the Measured Current is lower than L1.
8>.P-22:Relay ON when the Measured Current is higher than L2;Relay will keep ON no matter what the Measured Current is after relay turn on.Relay OFF if re-start power supply.
9>.P-31:Relay ON when the Measured Current is lower than L1;Relay OFF when the Measured Current is higher than L2.
10>.P-32:Relay ON when the Measured Current is lower than L1;Relay will keep ON no matter what the Measured Current is after relay turn on.Relay OFF if re-start power supply.
11>.P-41:Relay ON when the Measured Current is between L1 and L2;Otherwise relay OFF.
12>.P-42:Relay ON when the Measured Current is between L1 and L2;Relay will keep ON no matter what the Measured Current is after relay turn on.Relay OFF if re-start power supply.
13>.P-51:Relay ON when the Measured Current is lower than L1 or higher than L2;Otherwise relay OFF.
14>.P-52:Relay ON when the Measured Current is lower than L1 or higher than L2;Relay will keep ON no matter what the Measured Current is after relay turn on.Relay OFF if re-start power supply.

Using Steps:
 
1. Connect Current Transformer Sensor at ‘IN+’ and ‘IN-’.
2. Connect power supply DC 12V at ‘DC+’ and ‘DC-’(Please don’t connect load before set work mode).
3. Make sure what work mode require.
4. Keep press button K1 for more than 1second enter into set work mode as listing in ‘Function’.Press K2 and K3 to select mode.
5. Press button K1 at the second time to set the current lower limit value L1.Press K2 and K3 to change value.
6. Press button K1 at the third time to set the current upper limit value L2.Press K2 and K3 to change value.
7. Press button K1 at the fourth time to return to normal display current measured current.
8. Press button K3 to error calibration.
9. Test the set parameters based on the output indicator and the sound from the relay.
10. Cut off the power supply and then connect load at output.Note:The load needs to be powered separately.Module can not output voltage.
11. Turn ON power for module and use module.
 
Noted:
 
1. Its work voltage is DC 12V and not AC 220V.AC 220V is voltage for the Measured Current.
2. It’s a relay output.So it can not output voltage.It just like a switch.
3. User need provide power supply for load.
4. Wire cannot be reversed.Otherwise the module will be damaged.
 
Application:
 
1.Current check
2.Home security
3.Electrical inspection
4.Intelligent circuit control
5.Circuit detection
 
Package Included:
 
1 x  AC 220V 5A Current Detection Module
1 x Current Transformer Sensor




Reviews

There are no reviews yet.


Be the first to review “AC 220V 5A Current Detection Module Current Transformer Protection Board Current Transformer Sensor Module”

Your email address will not be published. Required fields are marked *


Q & A

There are no questions yet

Ask a question

Your question will be answered by a store representative or other customers.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Thank you for the question!

Your question has been received and will be answered soon. Please do not submit the same question again.

Error

Warning

An error occurred when saving your question. Please report it to the website administrator. Additional information:

Add an answer

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Thank you for the answer!

Your answer has been received and will be published soon. Please do not submit the same answer again.

Error

Warning

An error occurred when saving your answer. Please report it to the website administrator. Additional information:

Product ID: 9588878 Category: Voltage: 12V (+2 more)
Close My Cart
Close Wishlist
Close

Close
Navigation
Categories