HW-M543 DC12V~24V/AC220V Intelligent Digital Display Temperature and Humidity Controller

$39.59
  Availability: In Stock
  Shipping: Free Airmail 
  Estimated Delivery: 
   Bulk Savings (Buy more save more)
+
  •   Shipping Methods

    Handling Time

    Before we can ship your order, we prepare your products, do strict quality-control tests and carefully package the items. The time it takes to prepare your items for shipping is separate from the delivery time. It usually takes 1-3 business days to ship out .

    Shipping Methods

    You can choose the preferred shipping method on the cart page during the checkout process. We offers 3 international shipping methods:

    1. Airmail – Free untracked economy shipping via national postal services (HK Post, Singapore Post, China Post, PostNL, Swiss Post, Sweden Post, USPS, Royal Mail e.t.c.)
    2. Airmail Registered – Tracked shipping via national postal services (HK Post, Singapore Post, China Post, PostNL, Swiss Post, Sweden Post, USPS, Royal Mail e.t.c.)
    3. Expedited Shipping – Express shipping with courier delivery (DHL, UPS, FedEx, TNT)

    Delivery Time

    Airmail and Airmail Registered Area Estimated Delivery Time
    United States, Canada 7-25 business days
    Australia, New Zealand, Singapore, United Arab Emirates 10-25 business days
    United Kingdom, France, Spain, Germany, Netherlands, Japan, Belgium, Denmark, Finland, Ireland, Norway, Portugal, Sweden, Switzerland 10-25 business days
    Italy, Brazil, Russia, South Africa 10-45 business days
    Other countries 10-35 business days
    Expedited Shipping 3-10 business days to Worldwide

    Note: If you choose an expedited shipping, please remember to leave a valid contact number, this is required for expedited shipping’s courier delivery.

  •  Returns & Refund

    Last updated October 05, 2022

    Returns

    If you are not completely satisfied with your purchase for any reason, you may return it to us for a full refund within 15 days from delivery date. All returned items must be in new and unused condition, with all original tags and labels attached.

    Return Process

    To return an item, please email our customer service at sales@alexnld.com to obtain a Return Merchandise Authorization (RMA) number. After receiving a RMA number, place the item securely in its original packaging, and mail your return to the following address:

    Alex NLD
    Attn: Returns
    RMA #
    HaGiborim St 8
    Tiberias, 14388
    Israel

    Please note, you will be responsible for the return shipping charges. We strongly recommend that you use a trackable method to mail your return.

    All customers should contact us and obtain Return Merchandise Authorization (RMA) number before sending anything to us. We will not be responsible for returned item(s) without notifying us in advance.

    Refunds

    After receiving your return and inspecting the condition of your item, we will process your refund to the credit / debit card or PayPal account which was used to place the original order.

    Please allow at least seven (7) days from the receipt of your item to process your refund. Refunds may take 1-2 billing cycles to appear on your credit card statement, depending on your credit card company. We will notify you by email when your refund has been processed.

    Exceptions

    If an item is found damaged or defective on receipt, we kindly ask you to contact us within 15 days from the delivery date to arrange a refund or exchange without physical return of the item.

    Please provide us with following:

    1. Photos of the front and back sides of the packaging box;
    2. A photo, video or screenshot of the defective item or the defective part of the parcel.

    Our customer service team will communicate with you to arrange a refund or reshipment without physical return of the item.

    Warranty & Repair service

    If any of the items you have purchased from us is found defective within 1 year from receipt, you are entitled to a repair under warranty. Please kindly provide us with evidence photos or videos of the defective item. After providing such information to our Customer Service team  and the problem is acknowledged, you can send the items back to us for a repair.

    Note:  Please be aware, we do not cover the cost of the returns fees in  warranty & repair service.

    Order Cancellation

    If you want to cancel an order within 24 hours from confirmation of the payment, you will be entitled to a full refund. It is still possible to cancel an order after 24 hours, provided that it has not yet been shipped. If an order has been shipped, it’s impossible for us to cancel or modify it anymore. If you still want a refund, you required to return the item on it’s arrival.

    Questions

    If you have any questions concerning our return policy, please contact us at:

    +972 054-536-2888
    sales@alexnld.com

     


  Share
Specification:

Name: Digital Display Temperature and Humidity Controller
Brand: HW
Model: HW-M543
Control type: temperature and humidity
Working  Voltage: DC 12V~24V/AC 220V
Output capacity: maximum 10A
Measurement object: air, water
Temperature range: -20~60 ℃
Temperature measurement error: ±0.1 ℃
Humidity range: 0-100 %RH
Humidity measurement error: 0.2 %
Installation type: Embedded
Dimensions: 105*70*38 mm
Hole size: 81*57 mm
Weight: About 154g

Package included:

1 x Temperature and Humidity Controller

Setting instructions:

1. Correctly connect the power supply and the temperature and humidity control equipment according to the wiring diagram, pay attention not to connect the temperature and humidity control equipment wrongly. When connecting the DC12~24V power supply, you must distinguish the positive and negative poles. AC220V does not divide the zero live wire.

2. Stop temperature setting
Press the set button (SET), when the red screen number starts to flash, press the up and down buttons to adjust and set the stop temperature you want; after setting, wait for 10 seconds without operation, the system automatically saves the data.
3. Heating or cooling mode setting
Long press the up button, when the red screen displays C-0, press the set button to enter the C-0 mode setting, press the up and down buttons to switch between the blue screen L and H, L stands for heating, H stands for cooling. (Note: The temperature control load you connect to at L must be a heating device, and at H, the load you connect must be a refrigerating device.) After setting, wait 10 seconds, the system automatically saves the data.
4. Temperature difference setting
Long press the up key, when the red screen shows C-0, press the up and down keys to switch to the C-1 temperature difference setting, press the setting key again to enter the temperature difference setting, and then press the up and down keys to adjust the setting you want Temperature difference value; wait 10 seconds after setting, the system automatically saves the data. (If the stop temperature is set to 35C, the mode is set to L heating mode, and the temperature difference is set to 5, then the start temperature is 35-5=30°C and the temperature control range is between 30~35°C. On the contrary, if the mode is set to H cooling mode , Then the starting temperature is 35 + 5=40C, and the temperature control range is between 35~40℃)

5. Temperature calibration
Long press the up button, when the red screen displays C-0, press the up and down buttons to switch to the C-2 temperature correction mode, press the setting button once to enter the correction mode, and then press the up and down buttons to adjust and set the difference you want If the actual temperature is 28°C and the probe detection temperature is 28.2°C, then the correction difference can be set to -0.2; if the detection temperature is low, the correction difference can be adjusted higher. After setting, wait 10 seconds, the system will automatically save the data.

6. Stop humidity setting
Press the set button (SET), the red screen numbers start to flash, press the set button again to switch to the blue screen numbers flashing, and then press the up and down keys to adjust and set the stop humidity value you want; after setting, wait for 10 without operation Seconds, the system automatically saves the data.

7. Humidification or dehumidification mode setting
Long press the adjustment key, when the red screen displays H-0, press the set key to enter the H-0 mode setting, press the up and down keys to switch between the blue screen L and H, L stands for humidification, H stands for dehumidification. (Note: The humidity control load you connect to at L must be a humidifying device, and at H, the load you connect to must be a dehumidifying device.) After setting, wait 10 seconds, and the system automatically saves the data.

8. Humidity difference setting
Long press the adjustment key, when the red screen displays H-0, press the up and down keys to switch to the H-1 humidity difference setting, press the setting key to enter the humidity difference setting, press the up and down keys to adjust the setting you want After setting the difference, wait 10 seconds, the system automatically saves the data. (If the stop humidity is set to 50%RH, the mode is set to L humidification mode, the humidity difference is set to 5%RH, then the start humidity is 50-5=45%RH, and the humidity control range is between 45-50%RH, on the contrary If the mode is set to H dehumidification mode, then the starting humidity is 50 + 5 = 55%RH, and the humidity control range is between 50~55%RH)

9. Humidity calibration
Long press the adjustment key, when the red screen displays H-0, press the up and down keys to switch to the H-2 humidity correction mode, press the set key once to enter the correction mode, press the up and down keys to adjust the set difference; such as actual humidity It is 56%RH, the humidity detected by the probe is 56.2%RH, then the correction difference can be set to -0.2; if the detection temperature is low, the correction difference can be adjusted higher. After setting, wait 10 seconds, the system automatically saves the data.

Code

Name

Predetermined area

Default parameters

H-0

Mode setting

L: Humidify   H: Dehumidification

LHeating mode

H-1

  Humidity difference

0.1-50%RH

10%RH

H-2

Humidity           calibration

-10 and 10%RH

0.0%RH


10. Restore factory settings
Press the up and down keys at the same time for 5 seconds, when the screen displays 888, the factory restoration is complete.


Reviews

There are no reviews yet.


Be the first to review “HW-M543 DC12V~24V/AC220V Intelligent Digital Display Temperature and Humidity Controller”

Your email address will not be published. Required fields are marked *


Q & A

There are no questions yet

Ask a question

Your question will be answered by a store representative or other customers.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Thank you for the question!

Your question has been received and will be answered soon. Please do not submit the same question again.

Error

Warning

An error occurred when saving your question. Please report it to the website administrator. Additional information:

Add an answer

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Thank you for the answer!

Your answer has been received and will be published soon. Please do not submit the same answer again.

Error

Warning

An error occurred when saving your answer. Please report it to the website administrator. Additional information:

Product ID: 11383052 Category:
Close My Cart
Close Wishlist
Close

Close
Navigation
Categories