LC100-A High Precision Digital Inductance Capacitance Meter LC100A Multimeter Capacitance Meter Inductance Meter

$35.40
  Availability: In Stock
  Shipping: Free Airmail 
  Estimated Delivery: 
   Bulk Savings (Buy more save more)
+
  •   Shipping Methods

    Handling Time

    Before we can ship your order, we prepare your products, do strict quality-control tests and carefully package the items. The time it takes to prepare your items for shipping is separate from the delivery time. It usually takes 1-3 business days to ship out .

    Shipping Methods

    You can choose the preferred shipping method on the cart page during the checkout process. We offers 3 international shipping methods:

    1. Airmail – Free untracked economy shipping via national postal services (HK Post, Singapore Post, China Post, PostNL, Swiss Post, Sweden Post, USPS, Royal Mail e.t.c.)
    2. Airmail Registered – Tracked shipping via national postal services (HK Post, Singapore Post, China Post, PostNL, Swiss Post, Sweden Post, USPS, Royal Mail e.t.c.)
    3. Expedited Shipping – Express shipping with courier delivery (DHL, UPS, FedEx, TNT)

    Delivery Time

    Airmail and Airmail Registered Area Estimated Delivery Time
    United States, Canada 7-25 business days
    Australia, New Zealand, Singapore, United Arab Emirates 10-25 business days
    United Kingdom, France, Spain, Germany, Netherlands, Japan, Belgium, Denmark, Finland, Ireland, Norway, Portugal, Sweden, Switzerland 10-25 business days
    Italy, Brazil, Russia, South Africa 10-45 business days
    Other countries 10-35 business days
    Expedited Shipping 3-10 business days to Worldwide

    Note: If you choose an expedited shipping, please remember to leave a valid contact number, this is required for expedited shipping’s courier delivery.

  •  Returns & Refund

    Last updated October 05, 2022

    Returns

    If you are not completely satisfied with your purchase for any reason, you may return it to us for a full refund within 15 days from delivery date. All returned items must be in new and unused condition, with all original tags and labels attached.

    Return Process

    To return an item, please email our customer service at sales@alexnld.com to obtain a Return Merchandise Authorization (RMA) number. After receiving a RMA number, place the item securely in its original packaging, and mail your return to the following address:

    Alex NLD
    Attn: Returns
    RMA #
    HaGiborim St 8
    Tiberias, 14388
    Israel

    Please note, you will be responsible for the return shipping charges. We strongly recommend that you use a trackable method to mail your return.

    All customers should contact us and obtain Return Merchandise Authorization (RMA) number before sending anything to us. We will not be responsible for returned item(s) without notifying us in advance.

    Refunds

    After receiving your return and inspecting the condition of your item, we will process your refund to the credit / debit card or PayPal account which was used to place the original order.

    Please allow at least seven (7) days from the receipt of your item to process your refund. Refunds may take 1-2 billing cycles to appear on your credit card statement, depending on your credit card company. We will notify you by email when your refund has been processed.

    Exceptions

    If an item is found damaged or defective on receipt, we kindly ask you to contact us within 15 days from the delivery date to arrange a refund or exchange without physical return of the item.

    Please provide us with following:

    1. Photos of the front and back sides of the packaging box;
    2. A photo, video or screenshot of the defective item or the defective part of the parcel.

    Our customer service team will communicate with you to arrange a refund or reshipment without physical return of the item.

    Warranty & Repair service

    If any of the items you have purchased from us is found defective within 1 year from receipt, you are entitled to a repair under warranty. Please kindly provide us with evidence photos or videos of the defective item. After providing such information to our Customer Service team  and the problem is acknowledged, you can send the items back to us for a repair.

    Note:  Please be aware, we do not cover the cost of the returns fees in  warranty & repair service.

    Order Cancellation

    If you want to cancel an order within 24 hours from confirmation of the payment, you will be entitled to a full refund. It is still possible to cancel an order after 24 hours, provided that it has not yet been shipped. If an order has been shipped, it’s impossible for us to cancel or modify it anymore. If you still want a refund, you required to return the item on it’s arrival.

    Questions

    If you have any questions concerning our return policy, please contact us at:

    +972 054-536-2888
    sales@alexnld.com

     


  Share
Introduction:

Engineers engaged in electronic development often need to measure inductance and capacitance. Inductance and capacitance meters sold on the market are expensive and have large errors in measuring small inductances and small capacitances. This meter is based on the LC resonance principle and adds high-speed microcontroller precision measurement By calculation, it can measure inductances below 1uH and small capacitances less than 1pF. This is also a major feature of this instrument, which is especially suitable for microwave production and measurement of switching power supply transformer and filter inductances.

Gear position:

1. C file…… Capacitance (0.01pF-10uF)
2. L file…….. Inductance (0.001uH-100mH)
3. HL file……Large inductance (0.001mH-100H)
4. HC file…Large capacitor file (1uF-100mF)
All gears are automatic range, which is very convenient to use. In this way, LC100-A can replace any inductance and capacitance test instrument on the market in terms of measurement range and measurement precision. Its performance parameters are close to the digital bridge, and it is a cost-effective instrument.

USE:

1. Connect the computer USB as a power supply and switch tester.
2. According to the selection of the mode of the element to be measured, choose to measure inductance LX, capacitance CX, inductance or capacitance, HC HL, in the open state of the measuring terminal, you can see from the screen:
Inductance measurement 0.000uh LX:
Capacitance display: measure CX 0.00pf
The result shows: HL 0.000mh measured by large inductance
The measurement of large capacitance shows: HL 0.00uf
3. Due to the different measurement principles for HC files, first, the following three operation modes of LX, CX and HL are explained:
In the three modes, the requirements for zero point adjustment are measured. According to different methods of inductance and capacitance.
When the terminal is in CX mode, press the ‘Reset’ button, the screen displays ‘Settings…OK’ after launching, the screen displays ‘Timeline’ 0.00pf; in HL and LX modes, when the terminal is short-circuited, press the ‘Reset’ button, After the screen displays ‘Settings…Okay’, the screen should display ‘0.000mh’ and ‘0.000uh’, and the open end displayed ‘out of range!’. Then, you can connect the inductance to the tester for testing.
In the measurement result display, pressing the function key is all black, and the current of the test frequency will be displayed.
4. In the HC file, please make sure that the capacitor is completely discharged for measurement, then the red test fixture capacitor negative electrode, the black test clamp capacitor anode, you can read the test results of the display screen, note that the large-capacity measurement (over 10mf), the test time Can exceed 1 second, the longer the test time is for 100mf capacitors, the result is about 7-8 seconds ago.

Precautions:

1. When measuring electrolytic capacitors in HC mode, please note that the polarity is negative, red and black.
2. If the measurement is showing 0, it is sometimes necessary to adjust the zero. This may be a negative deviation, but it does not show negative.
3. It is strictly forbidden to press the reset button when testing the end element, this operation will lead to wrong results.
4. It is strictly forbidden to discharge untested capacitors, otherwise it may cause damage to the meter.
5. Use the 5V adapter module power supply, make sure the polarity is negative, otherwise the module will be damaged.

Warm reminder: Because the components themselves will have errors, the error is normal within 20%, so the above accuracy is in an ideal state, for reference only, please purchase with caution if you require high accuracy

Use skills and precautions:

1. Before measuring the inductance, first clear the short-circuit test clip to ensure the accuracy of the measurement;
2. Before measuring capacitance, clear the open-circuit test clip first to ensure accurate measurement;
3. When measuring the patch capacitance, you can clamp a piece of paper equivalent to the size of the capacitance in the patch test clip, and then reset it to zero, the result is more accurate;
4. When measuring electrolytic capacitors, please measure after discharging;
5. Do not use a longer test line when measuring. The shorter the test line, the smaller the interference and the higher the accuracy;

Frequently Asked Questions:

Question 1: How to calibrate this watch?
Answer: The test clip is disconnected, press and hold the red button, the LCD screen displays <DATA SAVE>, release the button at this time, and the calibration is successful.
Note: There should be no interference near the test clamp during calibration!

Question 2: Is the test clip in the instrument accessories a patch test clip?
Answer: The standard test clip of this meter is a pair of red and black alligator clips.

Question 3: Can the inductance of the transformer type be tested?
Answer: For inductors whose resistance exceeds 100Ω, our meter cannot be measured.

Question 4: How can I check the test frequency, can it be set?
Answer: The test frequency can be viewed by pressing the FUNC key during the test. It is automatically assigned by the MCU of the instrument, and it is not possible to set the test frequency by yourself.

Package includes:

1 x Digital Inductance Capacitance Meter

Reviews

There are no reviews yet.


Be the first to review “LC100-A High Precision Digital Inductance Capacitance Meter LC100A Multimeter Capacitance Meter Inductance Meter”

Your email address will not be published. Required fields are marked *


Q & A

There are no questions yet

Ask a question

Your question will be answered by a store representative or other customers.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Thank you for the question!

Your question has been received and will be answered soon. Please do not submit the same question again.

Error

Warning

An error occurred when saving your question. Please report it to the website administrator. Additional information:

Add an answer

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Thank you for the answer!

Your answer has been received and will be published soon. Please do not submit the same answer again.

Error

Warning

An error occurred when saving your answer. Please report it to the website administrator. Additional information:

Product ID: 11370429 Category:
Close My Cart
Close Wishlist
Close

Close
Navigation
Categories