XH-M453 Dual Digital Display Temperature Humidity Controller Thermostat Humidity Smart Thermostat Incubator Control AC 220V / DC12-24V

$25.99
  Availability: In Stock
  Shipping: Free Airmail 
  Estimated Delivery: 

+
  •   Shipping Methods

    Handling Time

    Before we can ship your order, we prepare your products, do strict quality-control tests and carefully package the items. The time it takes to prepare your items for shipping is separate from the delivery time. It usually takes 1-3 business days to ship out .

    Shipping Methods

    You can choose the preferred shipping method on the cart page during the checkout process. We offers 3 international shipping methods:

    1. Airmail – Free untracked economy shipping via national postal services (HK Post, Singapore Post, China Post, PostNL, Swiss Post, Sweden Post, USPS, Royal Mail e.t.c.)
    2. Airmail Registered – Tracked shipping via national postal services (HK Post, Singapore Post, China Post, PostNL, Swiss Post, Sweden Post, USPS, Royal Mail e.t.c.)
    3. Expedited Shipping – Express shipping with courier delivery (DHL, UPS, FedEx, TNT)

    Delivery Time

    Airmail and Airmail Registered Area Estimated Delivery Time
    United States, Canada 7-25 business days
    Australia, New Zealand, Singapore, United Arab Emirates 10-25 business days
    United Kingdom, France, Spain, Germany, Netherlands, Japan, Belgium, Denmark, Finland, Ireland, Norway, Portugal, Sweden, Switzerland 10-25 business days
    Italy, Brazil, Russia, South Africa 10-45 business days
    Other countries 10-35 business days
    Expedited Shipping 3-10 business days to Worldwide

    Note: If you choose an expedited shipping, please remember to leave a valid contact number, this is required for expedited shipping’s courier delivery.

  •  Returns & Refund

    Last updated October 05, 2022

    Returns

    If you are not completely satisfied with your purchase for any reason, you may return it to us for a full refund within 15 days from delivery date. All returned items must be in new and unused condition, with all original tags and labels attached.

    Return Process

    To return an item, please email our customer service at sales@alexnld.com to obtain a Return Merchandise Authorization (RMA) number. After receiving a RMA number, place the item securely in its original packaging, and mail your return to the following address:

    Alex NLD
    Attn: Returns
    RMA #
    HaGiborim St 8
    Tiberias, 14388
    Israel

    Please note, you will be responsible for the return shipping charges. We strongly recommend that you use a trackable method to mail your return.

    All customers should contact us and obtain Return Merchandise Authorization (RMA) number before sending anything to us. We will not be responsible for returned item(s) without notifying us in advance.

    Refunds

    After receiving your return and inspecting the condition of your item, we will process your refund to the credit / debit card or PayPal account which was used to place the original order.

    Please allow at least seven (7) days from the receipt of your item to process your refund. Refunds may take 1-2 billing cycles to appear on your credit card statement, depending on your credit card company. We will notify you by email when your refund has been processed.

    Exceptions

    If an item is found damaged or defective on receipt, we kindly ask you to contact us within 15 days from the delivery date to arrange a refund or exchange without physical return of the item.

    Please provide us with following:

    1. Photos of the front and back sides of the packaging box;
    2. A photo, video or screenshot of the defective item or the defective part of the parcel.

    Our customer service team will communicate with you to arrange a refund or reshipment without physical return of the item.

    Warranty & Repair service

    If any of the items you have purchased from us is found defective within 1 year from receipt, you are entitled to a repair under warranty. Please kindly provide us with evidence photos or videos of the defective item. After providing such information to our Customer Service team  and the problem is acknowledged, you can send the items back to us for a repair.

    Note:  Please be aware, we do not cover the cost of the returns fees in  warranty & repair service.

    Order Cancellation

    If you want to cancel an order within 24 hours from confirmation of the payment, you will be entitled to a full refund. It is still possible to cancel an order after 24 hours, provided that it has not yet been shipped. If an order has been shipped, it’s impossible for us to cancel or modify it anymore. If you still want a refund, you required to return the item on it’s arrival.

    Questions

    If you have any questions concerning our return policy, please contact us at:

    +972 054-536-2888
    sales@alexnld.com

     


  Share
Specifications:

Product model: XH-M453
Product specifications: DC12~24V/AC220V
Temperature range: -20~60°C
Humidity range: 0~100%RH
Control accuracy: ±0.1 °C / 0.2%
Detection probe: integrated sensor
Output type: relay output
Output capacity: up to 10A
Product weight: about 150g
Appearance size: 105*75*38mm
Embedded hole: 81*57mm

Package Included:

1 x XH-M453 Dual Digital Display Temperature Humidity Controller
1 x Sensor Cable

User Manal:

1. Connect the power supply and temperature control humidity equipment correctly according to the wiring diagram. Pay attention to the temperature control and humidity control equipment. Do not connect the wrong ones. When connecting the DC12~24V power supply, distinguish the positive and negative poles. AC220V does not divide the zero fire line.
2. Stop the temperature setting
Press the SET button. When the red screen number starts to flash, press the up and down buttons to adjust the desired stop temperature. After setting, wait for 10 seconds without waiting for the system to automatically save the data.
3. Heating or cooling mode setting
Press and hold the up key, when the red screen displays C-0, press the setting button to enter the C-0 mode setting.
The down button switches between blue screens L and H, where L stands for heating and H stands for cooling. (Note: L when you pick up
The temperature-controlled load must be a heating device. When H, the load you connect must be a cooling device. ) set well
Wait 10 seconds, the system automatically saves the data.
4. Temperature difference setting
  Press and hold the up key, when the red screen displays C-0, press the up and down keys to switch to the C-1 temperature difference setting, and then press
Set the temperature to the temperature difference setting, then press the up and down keys to adjust the temperature difference you want; set
Wait 10 seconds, the system automatically saves the data. (If the stop temperature is set to 35 ° C, the mode is set to L plus
In the hot mode, the temperature difference is set to 5, and the starting temperature is 35-5=30°C, and the temperature control range is between 30~35°C.
On the contrary, if the mode is set to H cooling mode, the starting temperature is 35+5=40°C, and the temperature control range is
Between 35~40°C)
5. Temperature calibration
Press and hold the up key, when the red screen displays C-0, press the up and down keys to switch to the C-2 temperature correction mode, press the set key to enter the calibration mode, and then press the up and down keys to adjust the difference you want. Value; if the actual temperature is 28 ° C, the probe detection temperature is 28.2 ° C, then the correction difference is set to -0.2; if the detection temperature is low, the correction difference can be increased. Wait 10 seconds after setting, the system automatically saves the data.

Temperature parameter code table:

Code    Name Setting range                                  Default parameters
C-0       mode setting L heating H cooling             L heating mode
C-1       temperature difference 0.1~50°                C 2.0°C
C-2       temperature calibration -10 and 10 °C      0.0 °C
6. Stop the temperature setting
   Press the SET button, the red screen number starts to flash, and then press the SET button to switch to the blue screen number.
Blink, press the up and down keys to adjust the desired stop humidity value; do not wait after setting 10
In seconds, the system automatically saves the data.
7. Humidification or dehumidification mode setting
   Press and hold the key, when the red screen displays H-0, press the setting button to enter the H-0 mode setting.
The down button performs switching between blue screens L and H, L for humidification and H for dehumidification. (Note: L when you pick up
The humidity control load must be a humidification device. When H is used, the load you are connected to must be a dehumidification device. ) set well
Wait 10 seconds, the system automatically saves the data.
8. Humidity difference setting

Press and hold the key, when the red screen displays H-0, press the up and down keys to switch to the H-1 humidity difference setting, press
Press the setting button to enter the humidity difference setting, press the up and down keys to adjust the setting you want, and set it.
Wait 10 seconds, the system automatically saves the data. (If the stop humidity is set to 50% RH, the mode is set to L plus
In wet mode, the humidity difference is set to 5% RH, the starting humidity is 50-5=45%RH, and the humidity control range is between 45~50%RH. On the contrary, if the mode is set to H dehumidification mode, the starting humidity is 50+. 5=55% RH, the humidity control range is between 50~55% RH)
9. Temperature calibration
Press and hold the key, when the red screen displays H-0, press the up and down keys to switch to the H-2 humidity correction mode.
Press the setting button to enter the calibration mode, press the up and down keys to adjust the setting difference; if the actual humidity is 56% RH,
The probe detects a humidity of 56.2% RH, and the correction difference is set to -0.2;
Low, just adjust the correction difference. Wait 10 seconds after setting, the system automatically saves the data.
Humidity parameter code table
Code             Name Setting range                                                       Default parameters
H-0               mode setting L humidification H dehumidification        L humidification mode
H-1               Humidity difference 0.1~50%RH                                    10%RH
H-2               Humidity Calibration -10 and 10%RH                             0.0%RH
10. Restore factory settings
   Press and hold the up and down keys for 5 seconds at the same time. When the screen displays 888, the factory will be restored.

Reviews

There are no reviews yet.


Be the first to review “XH-M453 Dual Digital Display Temperature Humidity Controller Thermostat Humidity Smart Thermostat Incubator Control AC 220V / DC12-24V”

Your email address will not be published. Required fields are marked *


Q & A

There are no questions yet

Ask a question

Your question will be answered by a store representative or other customers.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Thank you for the question!

Your question has been received and will be answered soon. Please do not submit the same question again.

Error

Warning

An error occurred when saving your question. Please report it to the website administrator. Additional information:

Add an answer

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Thank you for the answer!

Your answer has been received and will be published soon. Please do not submit the same answer again.

Error

Warning

An error occurred when saving your answer. Please report it to the website administrator. Additional information:

Product ID: 10561412 Category: Voltage: AC220V (+1 more)
Close My Cart
Close Wishlist
Close

Close
Navigation
Categories